Monogram ZDT800SIFII Installation Instruction

Page of 48
Installation Preparation
For models equipped with power cord: Do not modify the 
plug provided with the appliance; if it will not fit the outlet, 
have a proper outlet installed by a qualified technician.
Cabinet Preparation & Wire Routing
 The wiring may enter the opening from either side, rear or 
the floor within the shaded area illustrated above in Figure 
E and defined in Figure A.
• Cut a 1-1/2" maximum diameter hole to admit the 
electrical cable. Edges of hole should be smooth and 
rounded. Permanent wiring connections may pass 
through the same hole as the drain hose and hot water 
line, if convenient. If cabinet wall is metal, the hole edge 
must be covered with a bushing.
 
NOTE: 
Power cords with plug must pass through a
separate hole.
 
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
• For permanent connections the cable must be routed as 
shown in Figure E. Cable must extend a minimum of 24" 
from the rear wall.
• For power cord connections, install a 3-prong grounding 
type receptacle in the sink cabinet rear wall, 6" min. or 18" 
maximum from the opening, 6" to 18" above the floor. 
• Use the Power Cord Kit for your dishwasher model
.
PREPARE ELECTRICAL WIRING
Electrical Requirements
• This appliance must be supplied with 120V, 60 Hz., and 
  connected to an individual properly grounded branch 
circuit, protected by a 15- or 20-ampere circuit breaker 
or time-delay fuse.
• Wiring must be 2 wire with ground and rated for 75°C 
(167°F).
• If the electrical supply does not meet the above 
 requirements, call a licensed electrician before 
 proceeding.
Grounding Instructions–Permanent Connection
This appliance must be connected to a grounded metal, 
permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and be 
connected to the equipment-grounding terminal or lead on 
the appliance.
Grounding Instructions–Power Cord Models
This appliance must be grounded. In the event of a 
malfunction or breakdown, grounding will reduce the risk 
of electric shock by providing a path of least resistance 
for electric current. This appliance is equipped with a 
cord having an equipment-grounding conductor and 
a grounding plug. The plug must be plugged into an 
appropriate outlet that is installed and grounded in 
accordance with all local codes and ordinances.
White
18"
6"
24"
from Wall
3"
from
Cabinet
Alternate
Receptacle
Location
Ground
Black
1-1/2" Dia. Hole (Max.)
18"
6"
Receptacle
Location
Area
Figure E
WARNING:
FOR PERSONAL SAFETY: Remove house fuse or open circuit 
breaker before beginning installation. Do not use an extension 
cord or adapter plug with this appliance.
WARNING:
The improper connection of the equipment grounding 
conductor can result in a risk of electric shock. Check 
ZLWKDTXDOL¿HGHOHFWULFLDQRUVHUYLFHUHSUHVHQWDWLYH
if you are in doubt that the appliance is properly 
grounded.
5