Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the 
power burner is manufactured for. 
This natural gas power burner is designed to operate on natural gas ONLY, at a pressure regulated at 
4” (101.6mm) water column (W.C.) when equipped with the correct natural gas orifices on the valves 
and a natural gas regulator on the supply line regulated at the residential meter.   
IMPORTANT: Never connect the power burner to an unregulated gas supply. 
Natural  gas  connections  must  be  performed  by  a  licensed  contractor  or  local  gas  company 
representative. 
Natural Gas Hose and Regulator 
IMPORTANT: NEVER use power burner without leak testing this connection. 
Natural gas regulator model: GR120
 
Gas pressure: 4” (101.6mm)   
Maximum rate working pressure: 1/2 Psig 
 
 
 
 
Natural Gas Supply and Connection 
1.  Make sure all burner valves are in the “OFF” position 
2.  All NG units need to have a regulator and shut-off valve on the supply line. 
3.  All Pipe threads need to have proper, gas rated, outdoor rated thread sealant. Flare ends do not 
need or utilize pipe sealant. 
4.  Your NG Coyote power burner comes with a ½” regulator.   
a)  You need to seal the regulator to the hose using your pipe sealant. 
b)  Then attach the flare end to your manifold line, with no pipe sealant. 
c)  Next, attach your next connection hose (not included) to the other side of the NG regulator (it 
is also ½” MIP) 
i. 
We suggest using ½” stainless steel corrugated hoses for all NG Power burners 
ii. 
Make sure that you purchase a hose of adequate length and capacity for the intended 
application. 
d)  Connect the other end of this hose, to your shut off valve 
i. 
Depending on your choice of hose and shut-off, the nipple going into the shut-off valve 
may vary. 
e)  Test all connections for leaks with a soap and water solution. 
High Elevation Installation and Use 
Coyote  power  burners  are  designed  to  operate  most  efficiently  at  0-2000  feet  above  sea  level.  From 
2000-4000 feet above sea level you will not notice any substantial decrease in your heat, although more 
gas  is  combusting  within  the  burners  due  to  less  oxygen.  Above  4000  feet,  you may  experience  a  little 
longer cooking time on your power burner than you would experience at sea level. But again, this is just due 
to the air/fuel mixture taking place within the burners. If any problems or concerns exist about your location 
or elevation, please contact Coyote Customer Service for assistance. 
Natural Gas Hook-up