combustible material without an approved ventilation system directly located above the unit. 
 
For Built-in Installations 
A built-in power burner is designed for easy installation into masonry enclosures. For non-combustible 
applications, the power burner drops into the opening (as shown in cut-out detail drawing - Fig. A
and hangs from the power burner body itself. A bottom deck is not required to support the power burner 
from the bottom. It is also required that: 
• 
Two ventilation holes, of at least 20 sq inches in size, must be present to help release any gas 
from a leak and allow residual heat to dissipate. 
• 
The counter should be flat and level in reference to the floor.   
LP TANK STORAGE MUST BE ISOLATED IN A SEPARATE COMPARTMENT FROM THAT OF THE 
POWER BURNER AND IT MUST BE VENTED AS WELL. (RECOMMEND BOTTOM VENTS FOR LP) 
Cut out Dimensions Figure A 
 
 
 
 
 
 
Model 
Product 
Description 
Cutout Dimensions 
Overall Dimensions 
Total BTU 
Ratings 
Electrical 
Outlets (110V) 
  
  
Height  Width  Depth  Height  Width  Depth 
LP 
NG 
Qty Needed 
CPB 
Power Burner 
11 1/2" 
21" 
22 1/2" 
12 3/4" 
24" 
26" 
60,000 
60,000 
No Electrical