COYOTE CPB Manual
5
combustible material without an approved ventilation system directly located above the unit.
For Built-in Installations
A built-in power burner is designed for easy installation into masonry enclosures. For non-combustible
applications, the power burner drops into the opening (as shown in cut-out detail drawing - Fig. A)
and hangs from the power burner body itself. A bottom deck is not required to support the power burner
from the bottom. It is also required that:
•
Two ventilation holes, of at least 20 sq inches in size, must be present to help release any gas
from a leak and allow residual heat to dissipate.
•
The counter should be flat and level in reference to the floor.
LP TANK STORAGE MUST BE ISOLATED IN A SEPARATE COMPARTMENT FROM THAT OF THE
POWER BURNER AND IT MUST BE VENTED AS WELL. (RECOMMEND BOTTOM VENTS FOR LP)
Cut out Dimensions Figure A
Model
Product
Description
Cutout Dimensions
Overall Dimensions
Total BTU
Ratings
Electrical
Outlets (110V)
Height Width Depth Height Width Depth
LP
NG
Qty Needed
CPB
Power Burner
11 1/2"
21"
22 1/2"
12 3/4"
24"
26"
60,000
60,000
No Electrical