Sub-Zero IC36RIDLH Installation Instruction

Page of 44
subzero.com   
|
   7
SITE PREPARATION
CONCRETE WEDGE ANCHOR INSTALLATION:
1
   Drill  a 
3
/
8
"
 (10)
 diameter hole any depth exceeding the 
minimum embedment. Clean the hole or drill additional 
depth to accommodate drill fines.
2
   Assemble the washer and nut flush with the end of 
anchor to protect threads. Drive the anchor through the 
material to be fastened until the washer is flush with the 
surface material.
3
   Expand the anchor by tightening the nut 3–5 turns past 
hand-tight position or to 25 foot-pounds of torque.
 WARNING
Verify there are no electrical wires or plumbing in the 
area which the screws could penetrate.
 CAUTION
Always wear safety glasses and use other neces-
sary protective devices or apparel when installing or 
working with anchors.
Anchors are not recommended for use in lightweight 
masonry material such as block or brick, or for use in 
new concrete which has not had sufficient time to cure. 
The use of core drills is not recommended to drill holes 
for the anchors.
Anti-Tip Bracket
WOOD FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening, 
drill pilot holes 
3
/
16
"
 (5)
 diameter maximum in the wall studs 
or wall plate. Use the #12 screws and washers to secure the 
brackets. Verify the screws penetrate through the flooring 
material and into wall studs or wall plate a minimum of 
3
/
4
"
 
(19)
. Refer to the illustration and chart below. 
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening, 
drill pilot holes 
3
/
16
"
 (5)
 diameter maximum in the wall studs 
or wall plate. Drill 
3
/
8
"
 (10)
 diameter holes into the concrete 
a minimum of 1
1
/
2
"
 (38)
 deep. Use the #12 screws and 
washers to secure the brackets to the wall, and use the 
3
/
8
wedge anchors to secure the brackets to the floor. Verify the 
screws penetrate wall studs or wall plate a minimum of 
3
/
4
"
 
(19)
. Refer to the illustration and chart below.
ANTI-TIP BRACKET PLACEMENT
WIDTH
A
18" Models
9"
 (229)
24" Models
12"
 (305)
27" Models
13
1
/
2
"
 (343)
30" Models
15"
 (381)
36" Models
18"
 (457)
A
A
SUBFLOORING
WOOD FLOOR
WALL PLATE
FINISHED
FLOORING
A
A
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
1
1
/
2
"
(38)
min
 
Wood floor.
 
Concrete floor.