Sub-Zero 700TCILH Installation Instruction

Page of 3
Sabbath Mode Accessory 700 Tall Series 
(700TR, 700TC/I, 700TFV, 736TC/I)4204500
When placed in Sabbath Mode with addition of harness, unit will operate as described below:
The door can be opened/closed at any time without concern of directly turning on or off any lights, or affecting 
digital readouts, solenoids, fans, valves, compressors, icons, tones or alarms. 
Any defrost cycle that becomes active will not be a function of number of times or length of 
time that door is opened. 
The ice maker is disabled automatically ( where applicable).  Ice cubes can then be made manually 
(using a standard ice cube tray) as needed for that Sabbath/Holiday. 
All dispenser functions are deactivated. 
In the event of a power failure, unit will return to mode when power is restored.
INSTALLATION PROCEDURE:
Included in this package are two relay harnesses: one with
a longer white wire, and one with a shorter white wire. A
harness is needed for both upper and lower sections of unit. 
NOTE: Unplug unit. Severe shock may occur during
installation if not unplugged. Installer will be handling
live wires if unit is not unplugged.
NOTE: Wires colors may vary from unit to unit. Use
included illustrations for installation when actual colors
on unit differ from instructions.
UPPER SECTION (DOOR SECTION):
1.
Locate relay harness with shorter white wire.
2.
Remove trim piece at top of unit that covers switch
box. Remove switch box by removing screws 
fastening it to top of unit (See Fig. 1).
3.
There should be 5 wires atop unit. With unit off,
remove yellow wire from light switch and both wires
from fan switch.
4.
The following connections should be made between
cabinet harness and relay harness (See Fig. 2):
A. Yellow relay harness wire to yellow cabinet wire.
B. Fan switch wire (from compressor; on some units, 
wires to fan switch are same color. It must be wire 
from compressor--or board when off-cycle fan is 
enabled) from cabinet to black relay harness wire.
C. Other fan switch wire from cabinet to red 
harness wire.
5.
The following connections should be made between
relay harness and switches on unit (See Fig. 2):
D. Yellow relay harness wire to light switch.
E. Purple relay harness wire to fan switch.
F. Red relay harness wire to fan switch.
G. Re-install switch box being sure that all wires and 
relay are inside switch box.
H. Re-install trim piece.
D
A
E
F
B
C
Splice these two
white wires together
Wiring Connections
Figure 1
Figure 2
Page 1 of 3
3758572 / Rev B / February 2006
CONTAINS:
QUANTITY
PART NUMBER
DESCRIPTION
1
3024970
W/H, Star-K Assy. O/U
1
3026170
W/H, Star-K Assy. 700 Series
1
3752840
Bag, Zip-Lock 10 x 12
1
3758573
Diagram, 700 Tall Star-K Wiring
1
6120440
Wire Splice, #53440-2
1
6230640
Tape, Double-Sided Sided 1/2'' Wide
1
3758572
Instructions, Star-K, 700 Tall