I N S TA L L AT I O N
R E C O M M E N D A T I O N S
S I T E P R E P A R A T I O N
Make sure that the finished rough opening
where the undercounter unit is to be installed
is properly prepared. Refer to the installation
specifications illustration for rough opening
dimensions, door swing clearance and location
of electrical and plumbing (model UC-24C).
IMPORTANT NOTE: To operate properly, the
door must open a minimum of 90˚. Use a
minimum 3" (76) filler in corner installations to
assure a 90˚ door opening. Allow enough clear-
ance in front of the unit for full door swing.
IMPORTANT NOTE: Make sure the floor under
the unit is level with the surrounding finished
floor.
T O O L S A N D M A T E R I A L S R E Q U I R E D
The following is a list of tools and materials
that should be available for proper installation.
Appliance dolly able to support 130 lbs
(59 kg)
Level—2' (.6 m) and 4' (1.2 m)
recommended
Phillips and slotted screwdriver sets
Wrench set and allen wrench set
Crescent wrenches
Various sized pliers
5
/
16
" hex bolt nut driver
Drill and assorted drill bits
4' (1.2 m) of
1
/
4
" copper tubing and
saddle valve (4200880) for the water line
(model UC-24C)
Copper tubing cutter (model UC-24C)
Masonite, plywood,
1
/
8
" pressed fiberboard,
cardboard or other suitable material to
protect finished flooring
3
Dimensions in parentheses are in
millimeters unless otherwise specified.
U N D E R C O U N T E R
I N S T A L L A T I O N I N S T R U C T I O N S
23
7
/
8
"
(606) 
90˚
145˚ 
MAXIMUM 
DOOR SWING 
44" 
(1118) 
DOOR CLEARANCE 
26"
(660)
DOOR CLEARANCE 
25
3
/
8
"
(644)
25
3
/
8
"
(645)
I N S T A L L A T I O N S P E C I F I C A T I O N S
NOTE: Door swing clearances are based on stainless
steel door and handle dimensions.
34
1
/
2
"
(876)
ROUGH
OPENING
HEIGHT
34
1
/
4
"
(870)
MINIMUM
HEIGHT
REQUIRED
24" 
(610)
ROUGH OPENING
WIDTH
15
1
/
2
"
(394)
LOCATE ELECTRICAL
AND WATER LINE
(MODEL UC24C ONLY)
WITHIN SHADED AREA
3"
(76)
2"
(51)
FRONT VIEW
ANTI-TIP BRACKET
24"
(610)
ROUGH
OPENING
DEPTH
LOCATE WATER LINE
(MODEL UC24C ONLY)
WITHIN SHADED AREA
15
1
/
2
"
(394)
1
/
2
"
(13)
2"
(51)
TOP VIEW
NOTE: Water line is required for model UC-24C only.