Monogram ZIP360NH Specification Sheet

Page of 3
STANDARD INSTALLATION
ANTI-TIP BRACKET
35 1/2"
 
(90.2)
2 5/16"
(5.9)
*84"
(213.4)
*Trim will overlap
additional 7/16"
24"
 
(61.0)
2"
(5.1)
4 13/16"
(12.2)
7/16"
 (1.1)
Trim overlap
3 1/2"
(8.9)
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
6"
(15.2)
10"
(25.4)
5"
(12.7)
5"
(12.7)
WATER
SIDE VIEW INSTALLED
UNDER SOFFIT
     ZIPP360NZ
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
24" 
(61.0)
3/16"
(.5)
1 7/8"
(4.8)
*84”
(213.4)
*Depending
on installation
*84"
(213.4)
*Depending
on installation
*3" - 4"
(7.6 - 10.2)
*Depending
on installation
height
2 9/16"
(6.5)
*84"
(213.4)
*Or installation
height from floor
Screws mounted
into vertical wall
studs
2" x 4"
Cut to 35" Length
SOFFIT
ELEC.
W
SIDE VIEW
FRONT VIEW
A   Mounting the junction 
box in this location will 
also allow for front 
accessability through 
access panel.
B   Water supply area
 WARNING:
The refrigerator is top 
heavy and must be secured 
to prevent the possibility of 
tipping forward.  Failure to 
do so may result in death 
or serious injury.
The information below is 
for cabinet design only.  
When installing the anti-
tip system you must use 
the product installation 
instructions.
The information below 
applies to all installation 
constructions:
•  A wall bracket, bolts and 
toggles will be supplied 
with the unit.
•  The bolts will be used to 
attach bracket to wall in 
4 locations. Two of the 
locations must penetrate 
the center of the wall 
studs.
•  The toggles are used for 
stability in drywall and 
when metal studs are 
encountered. Lag bolts 
are used in wood studs.
•  In installation opening, 
measure 81 ½” from  
floor and draw a 
horizontal line.
•  Locate and mark the wall 
studs on horizontal line.  
Verify at least two studs 
have their centerlines 
within the center 32.5” 
of installation opening to 
ensure 2 wall studs are 
penetrated.
•  The bracket will be 
centered left to right in 
opening with bottom of 
bracket on the horizontal 
line.
•  When unit is placed in 
opening, the bracket tabs 
will align with openings 
in back of the unit.  The 
unit will be secured to the 
bracket using supplied 
“L” bolts.
See Installation 
Instructions for detailed 
instructions.
GE Monogram
®
 36" Built-In French-door Bottom-freezer
A
B
Product Specification Created 8/14
ZIPP360NH
24"
 
(61.0)
1 1/2"
(3.8)
3"
(7.6)
7/16"
 (1.1)
Trim overlap
35 1/2"
 
(90.2)
2 5/16"
(5.9)
SIDE VIEW
FRONT VIEW
ZIC360NXRH
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10" 
(25.4)
Use two 
additional hole 
locations at end 
of brackets
Wall
Studs
Bracket 
mounted
into vertical 
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
NOTES