Grounding Instructions for a 
Permanently Connected Appliance
This unit must be grounded to operate properly. It 
must be connected to a grounded metal, permanent 
wiring system, or an equipment-grounding conductor 
must be run with the circuit conductors and 
connected to the equipment grounding terminal or 
lead of the appliance.
Damage to the dishwasher could occur if it is not 
properly grounded.
A three conductor electrical cable or conduit meeting 
local codes and ordinances is required. A UL listed 
strain relief is required if non-metalic cable is used. 
Suggested color coding: black, white and green.
Circuit Requirements
The wiring from the electrical outlet or junction box 
shall be connected to a circuit protected by a 15 
Amp. circuit breaker or time delay fuse, installed by a 
licensed electrician.
Water Supply Specifications
 WARNING
In order to prevent heat damage, all solder 
connections for the water line connected to the 
water supply valve must be made before the 
dishwasher water supply line is connected.
•  The dishwasher can be connected to a cold or 
hot water supply (maximum 160°F, 70°C). Dacor 
recommends using a hot water supply of 120°F 
(49°C) to 140°F (60°C). If a cold water supply is 
used, the washing times will be longer, but the 
performance will not be affected.
•  The water supply pressure must be between 4.2 
and 140 psi (30 - 1000 kPa). The water supply 
line and the shut-off valve must supply a flow 
volume of at least 3 gallons (12 liters) per minute. 
•  Install a 3/8” water supply valve for connection to 
the dishwasher’s water supply line in a location 
where it is easily accessible after the dishwasher 
is installed. 
•  The dishwasher water supply line is equipped 
with a 3/8” (1.0 cm) NPT female compression 
fitting on the end.
Preparing for Installation
Electrical Specifications
 WARNING
Electrical and grounding connections must comply 
with the applicable portions of the national electrical 
code and/or other local electrical codes.
This dishwasher comes with an electrical cord with 
a three prong grounding plug 
for a 120 Vac, 15 Amp. power 
supply. Plug it only into a 120 
Vac, three prong, grounding 
electrical outlet located to 
either side of the dishwasher 
cutout.
If the cord is not long enough, or if a hard-wire 
installation is needed, follow the instructions on  
page 9.
Electrical Requirements
Electrical Circuit 
Requirements
15 Amp. 120 Vac, 60 Hz. 
dedicated, grounded, circuit. 
Total Connected Load
11 Amp. @ 120 Vac, 60 Hz.*
* For reference only. For exact specifications see the 
product data label, located inside the right door jamb.
Grounding Instructions for a Cord-
Connected Appliance
This appliance must be grounded. In the event of 
a malfunction or breakdown, grounding will reduce 
the risk of electric shock by providing a path of least 
resistance for electric current. This appliance is 
equipped with a cord having an equipment-grounding 
conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is installed 
and grounded in accordance with all local codes and 
ordinances.
 WARNING
•  Improper connection of the equipment-
grounding conductor can result in a risk 
of electric shock. Check with a qualified 
electrician or service representative if you are 
in doubt whether the appliance is properly 
grounded. Do not modify the plug provided with 
the appliance, if it will not fit the outlet, have a 
proper outlet installed by a qualified electrician.
•  Do not use an extension cord with this 
appliance.
 WARNING
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.