2. Remove 4 screws attaching the terminal box cover. 
3. Determine which direction (front or rear) the home power 
supply cable will enter the terminal box. Remove the 
appropriate knockout from the front or rear panel and install a 
¹⁄₂" (12.7 mm) UL listed or CSA approved conduit connector.
4. Using 2 or more people, insert the downdraft vent into the 
countertop cutout. Position downdraft vent so it is centered 
in the cutout with the rear flange over the edge of the cutout 
and the rear of the vent box against the edge of the cutout.
5. Drill 2 pilot holes through each of the undercounter mounting 
brackets into the underside of the countertop. Using 2 screws 
(not provided) of the appropriate length, mount the brackets 
to the countertop.
IMPORTANT: Select a screw length that will not allow the 
screws to go through the countertop when tightened.
6. Check that the downdraft vent is level vertically. Loosen the 
lower support legs screws and position the legs against the 
cabinet floor.
7. Fasten the lower support legs to the cabinet floor with screws 
(not provided).
8. Tighten the lower support legs screws.
Make Electrical Connections
1. Disconnect power.
A. Terminal box cover
A. Rear flange of downdraft vent
B. Edge of cutout in countertop
C. Rear of downdraft vent
D. Cabinet back
E. Lower support leg
F. Cabinet floor
G. Countertop
A
A
C
B
D
E
F
G
A. Screws
B. Backsplash
C. Countertop
A. Screw (not provided)
A
B
C
A
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.