Scholtes LFDS3XL60HZ Use & Care Manual

Page of 96
EN
11
Fig. 5-10
Connecting to a "T" union of the drain circuit
Make the connection upline from the siphon of the drain
line and at least 400 mm (15-3/4") above the floor on
which the dishwasher will be installed.
1. Connect the dishwasher drain hose (ref. A fig. 5-11) to
the "T" union (ref. B fig. 5-11) of the drain circuit using a
38 to 50 mm (1-1/2 to 2") screw clamp* (ref. C fig. 5-11);
if necessary, cut the end of the dishwasher drain hose
(ref. D fig. 5-11) (do not cut the corrugated section).
* Available from any plumbing stockist
Fig. 5-11
Connecting to a waste disposal unit with an air gap
Make the connection upline from the siphon of the drain
line and at least 400 mm (15-3/4") above the floor on
which the dishwasher will be installed.
1. Remove the cover of the waste disposal unit (ref. A
fig. 5-12).
2. Connect the dishwasher drain hose (ref. B fig. 5-12) to
the air gap (ref. C fig. 5-12) using the wide spring
clamp (ref. D fig. 5-12); if necessary, cut the end of the
dishwasher drain hose (ref. E fig. 5-12) (do not cut the
corrugated section). If the drain hose has been cut,
use a 38 to 50 mm (1-1/2 to 2") screw clamp*.
3. To connect the air gap (ref. C fig. 5-12) to the waste
disposal unit inlet (ref. F fig. 5-12), use a rubber union*
(ref. G fig. 5-12) with spring or screw clamps* (ref. H
fig. 5-12).
* Available from any plumbing stockist
Fig. 5-12
Connecting to the air gap (no waste disposal unit)
Make the connection upline from the siphon of the drain
line and at least 400 mm (15-3/4") above the floor on
which the dishwasher will be installed.
1. Connect the dishwasher drain hose (ref. A fig. 5-13) to
the air gap (ref. B fig. 5-13) using the wide spring
clamp (ref. C fig. 5-13); if necessary, cut the end of the
dishwasher drain hose (ref. D fig. 5-13) (do not cut the
corrugated section). If the drain hose has been cut,
use a 38 to 50 mm (1-1/2 to 2") screw clamp*.
2. To connect the air gap (ref. B fig. 5-13) to the "T" union
(ref. E fig. 5-13) of the drain line, use a rubber union*
(ref. F fig. 5-13) with spring or screw clamps* (ref. G
fig. 5-13).
* Available from any plumbing stockist