Electrolux EI23BC30KS Data Sheet

Page of 2
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° 
CONTROL SETTING (2500++  CONTROL)
Variable Speed Compressor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
32 to 40%
100%
Freezer Temperature
-6° to 6°F 
-21° to -14°C
-6° to 6°F
-21° to -14°C
Refrigerator Temperature
33° to 46°F 
0.5° to 8°C
33° to 46°F
0.5° to 8°C
Low Side Pressure
(cut-in)  
5 to 12 psig
34 to 83 kPa
N/A
Low Side Pressure
(cut-out)  
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure 
85 to 95 psig
586 to 655 kPa
120 to 135 psig
827 to 931 kPa
Wattage 
40 to 55
60 to 70
Amps (running)
0.5 to 1.1
0.7 to 0.9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-
out
Watts
Ohms
23’ SD, 28’ SD, 23’ CD
25°F 
(-4°C)
47°F
(8°C)
500
26
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
(Energy Star, some models)
1100 CW 
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F (9°C), Closes at 15°F (-9°C)
Heater Voltage
115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
 
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO 
NOT allow torch to touch insulation; it will char at 200°F and flash ignite 
(burn) at 500°F. Excessive heat will distort the plastic liner.
SERVICE DATA SHEET
242199300
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a  
System Diagnostic Mode
Activate:
Press 
FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously.
Press 
FF UP to advance through tests.
Deactivate:
Press 
FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of 
inactivity. 
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
All LED lights on UI illuminated
--
Second Screen
--
All segments on UI temperature displays illuminated
--
Third Screen
--
Blank UI display, no lights illuminated, no shadowing; “-” and “+” 
blinking on FF display side to show location.
28
Dispenser Paddle
Press disp. paddle
“on” on UI when depressed; “off” when released
1*
Standard 
Compressor
Press power on-off
Compressor running when “on”; stopped when “off”
2
Defrost Heater
Press power on-off
Defrost limit switch must be closed; verify “CL” in test 26.
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
3
FF Light
Press power on-off
With FF door open, FF lights on when “on”; off when “off”
8
Water Valve 
(Dispenser)
Press power on-off
FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
9
FZ Light
Press power on-off
With FZ door open, FZ lights on when “on”, off when “off”
10
Auger Motor
Press power on-off
FF door must be closed.
Motor running when “on”; motor stopped when “off”
11
Cube/Crush 
Solenoid
Press power on-off
FF door must be closed. 
Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”
41*
Perfect Temp Drawer 
(PTD)
Press power on-off
PTD UI illuminated when “on”, off when “off”
12*
VCC Condenser Fan
Press power on-off
Fan running when “on”; stopped when “off”
38*
VCC Compressor
Press power on-off
Compressor running when “on”; stopped when “off”
15 
Evaporator Fan
Press power on-off
Fan running for 
minimum of 10 sec. when “LO” or “HI”; stopped when 
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for 
speed change from “LO” to “HI”.
22
Damper
Press power on-off
With inspection mirror, observe damper open when “OP”; closed when “CL”
23
FF Door
Open/close FF door
“CL” on UI when door closed; “OP” when open
24
FZ Door
Open/close FZ door
“CL” on UI when door closed; “OP” when open
26
Defrost Limit Switch
Activates automatically
“CL” on UI when closed; “OP” when open
36
Ice Chute Door
Depress ice chute door 
or press power on-off
“OP” on UI when manually opened; “CL” when closed. Or, using “power on-
off”, “OP” on UI when solenoid activated, “CL” when deactivated
29
FF Thermistor Mid-
level
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of 
temperature measured with gauge at mid-level FF thermistor location. 
“OP-” if open; “SH-” if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature 
measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
33
Ambient Thermistor 
@ Main Board
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F of 
temperature measured with gauge at main board location. 
“OP” if open; “SH” if short
35*
FF Thermistor 
Upper-Level
Activates automatically
UI shows temperature sensed by upper level FF thermistor; pass if within 
10°F of temperature measured with gauge at upper-level FF thermistor loca-
tion. “OP¯” if open; “SH¯” if short 
34*
Ambient Thermistor 
@ UI
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera-
ture measured with gauge at UI location. “OP” if open; “SH” if short
0-
Firmware 
Parameters
Press power on-off
Displays digit sequence; record
2-
Main Board 
Firmware
Press power on-off
Displays digit sequence; record
4-
UI Firmware
Press power on-off
Displays digit sequence; record
 
IMPORTANT SAFETY NOTE
The  information  provided  herein  is  designed  to  assist  qualified  repair  personnel  only.  Untrained  persons 
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before 
servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position 
and properly secured.
Error Codes
Special Modes
Display
Interpretation
Mode
Display
Activate/Deactivate
(press for up to 10 sec. simultaneously)
FZ
FF
FZ
FF
--
OP
Open FF Thermistor
Manual Defrost
d
F
FF UP and FF DOWN / same to deactivate
OP
--
Open FZ Thermistor
Display / Showroom
77
77
FZ UP and FF DOWN / Power-on-Reset 
(POR)
--
SH
Shorted FF Thermistor
Sabbath
Sb
Sb
FZ DOWN and FF UP / same to deactivate
SH
--
Shorted FZ Thermistor
System Diagnostic
No FF or FZ display, 
all UI LEDs on.
FZ UP and FZ DOWN / FF UP to deactivate
SY
CF
UI to Main Control 
Board communication 
failure; on start up
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring. 
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
SY
CE
UI Main Control  Board 
communication error; 
after a period in operation
SY
EF
Evaporator Fan Failure
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at  bottom and pry-
ing cover from housing. Use screwdriver to rotate motor gear counterclockwise until 
holding switch circuit is completed. All components of ice maker should function to 
complete the cycle.  
Water Fill Volume: The water fill adjustment screw will change the fill time. 
One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 
4.3 oz.). When a water valve is replaced, the fill volume must be checked.      
TU
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
  
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.  
                                                                                                   
POWER
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BL
K
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
YELLOW
BRN
RED
GRN / YEL
RED
RED
LT. BLUE
P-3
P-1
P-2
P-4
ICE MAKER
LT. BLUE