Intel Pentium D 940 HH80553PG0884M User Manual
Product codes
HH80553PG0884M
Electrical Specifications
22
Datasheet
I
ENHANCED_
AUTO_HALT
Processor number
Extreme Edition 965
Extreme Edition 955
Extreme Edition 955
960
950
940
950
940
I
CC
Enhanced Auto Halt for
775_VR_CONFIG_05B
(Performance)
(Performance)
3.73 GHz
3.46 GHz
3.60 GHz
3.40 GHz
3.20 GHz
3.46 GHz
3.60 GHz
3.40 GHz
3.20 GHz
—
—
68
68
60
60
60
68
60
60
60
A
Processor number
960
950/945
940/935
930/925
920/915
940/935
930/925
920/915
I
CC
Enhanced Auto Halt for
775_VR_CONFIG_05A
(Mainstream)
(Mainstream)
3.60 GHz
3.40 GHz
3.20 GHz
3.00 GHz
2.80 GHz
3.40 GHz
3.20 GHz
3.00 GHz
2.80 GHz
—
—
48
48
48
48
48
48
48
48
48
I
TCC
I
CC
TCC active
—
—
I
CC
A
12
V
TT
FSB termination voltage
(DC + AC specifications)
(DC + AC specifications)
1.14
1.20
1.26
V
13, 14
VTT_OUT_
LEFT and
VTT_OUT_
RIGHT I
LEFT and
VTT_OUT_
RIGHT I
CC
DC Current that may be drawn from VTT_OUT_LEFT and
VTT_OUT_RIGHT per pin
VTT_OUT_RIGHT per pin
—
—
580
mA
I
TT
Steady-state FSB termination current
—
—
4.5
A
15, 16
I
TT_P
OWER
-
UP
Power-up FSB termination current
—
—
7.5
A
I
CC_VCCA
I
CC
for PLL lands
—
—
70
mA
I
CC_VCCIOPLL
I
CC
for I/O PLL land
—
—
52
mA
I
CC_GTLREF
I
CC
for GTLREF
—
—
200
μA
NOTES:
1. Unless otherwise noted, all specifications in this table are based on estimates and simulations or empirical data. These
specifications will be updated with characterized data from silicon measurements at a later date.
2. Adherence to the voltage specifications for the processor are required to ensure reliable processor operation.
3. Each processor is programmed with a maximum valid voltage identification value (VID), which is set at manufacturing and can
not be altered. Individual maximum VID values are calibrated during manufacturing such that two processors at the same
frequency may have different settings within the VID range. Note that this differs from the VID employed by the processor during
a power management event (Enhanced Intel SpeedStep technology or Enhanced HALT State).
4. These voltages are targets only. A variable voltage source should exist on systems in the event that a different voltage is required.
See
for more information.
5. The voltage specification requirements are measured across VCC_SENSE and VSS_SENSE lands at the socket with a 100 MHz
bandwidth oscilloscope, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire
on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe.
for the minimum, typical, and maximum V
CC
allowed for a given current. The processor should not
be subjected to any V
CC
and I
CC
combination wherein V
CC
exceeds V
CC_MAX
for a given current.
7.
I
CC_MAX
specification is based on V
CC
Maximum loadline. Refer to
for details.
8. I
CC_RESET
is specified while RESET# is active.
9. The current specified is also for AutoHALT State.
10.I
SGNT
and I
CC_ENHANCED_AUTO_HALT
are specified at V
CC_TYP
and T
C
= 50 °C.
11.These parameters are based on design characterization and are not tested.
12.The maximum instantaneous current the processor will draw while the thermal control circuit is active (as indicated by the
assertion of PROCHOT#) is the same as the maximum I
CC
for the processor.
13.V
TT
must be provided via a separate voltage source and not be connected to V
CC
. This specification is measured at the land.
14.Baseboard bandwidth is limited to 20 MHz.
Table 4.
Voltage and Current Specifications
Symbol
Parameter
Min
Typ
Max
Unit Notes
1, 2