Product Dimensions
COOKTOP WIDTH (A)
EG366
35 7/8” (911 mm)
EG486
47 7/8” (1216 mm)
Installation Requirements
 WARNING
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.
To prevent an electric shock hazard, the power sup-
ply must meet the specifications stated below. 
The electrical and gas supply data on this page is for refer-
ence only. If the requirements below do not agree with the 
product data label, use the data on the product data label.
Electrical Requirements
The electrical installation, including minimum supply 
wire size and grounding, must be done in accordance 
with National Electric Code ANSI/NFPA 70 and local 
codes and ordinances. A copy of this standard may be 
obtained from:
 
National Fire Protection Association 
 
1 Batterymarch Park  
 
Quincy, MA 02269-9101
The correct voltage, frequency and amperage must be 
supplied to the electrical outlet according to the product 
data label located on the bottom of the chassis.
The electrical outlet must be installed by a licensed 
electrician.
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
Total Connected Load
120 Vac 60 Hz,  
15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
Gas Supply Requirements
Check your local building codes for the proper method 
of installation. In the absence of local codes, this 
appliance should be installed in accordance with the 
National Fuel Gas Code ANSI Z223.1/NFPA 54. The 
gas service must be installed by a qualified profes-
sional
Be certain that the cooktop being installed is correct for 
the gas service being provided (natural gas or LP gas). 
Also, if operating the cooktop at an altitude above 4000 
ft. (1219 m) make sure it is equipped for high altitude 
operation. See the inside cover for more information.
An external manual shut-off valve must be installed 
between the gas inlet and the cooktop for the purpose 
of turning on or shutting off gas to the appliance.
The factory provided regulator shipped with the appli-
ance must be installed in the gas line that runs from the 
gas shut off valve to the cooktop gas inlet. Use only the 
regulator provided. The regulator inlet accommodates 
a 3/4” gas supply line and is also compatible with a 
1/2” house gas supply. The inlet to the cooktop itself is 
equipped with a 3/4” male NPT fitting.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold 
Pressure
Minimum Gas 
Supply Pressure
Natural Gas
5” Water Column 6” Water Column
Propane (LP)
10” Water
Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
A
4” (102 mm)
5/8” 
(16 mm)
7 3/4”
 (197 mm)
Trim:
7/16”
 (11 mm)
thick
26” (660 mm)
1 1/2” (38 mm) cooking surface 
height (grate level) above 
countertop
3/4” gas inlet, connects to regulator from 
bottom or rear of unit, end is recessed 
2” (51 mm) from chassis bottom
27” (686 mm)
28” (711 mm)
Power cord
32” long
Product tolerances: ±1/16” (±1.6 mm) unless otherwise 
noted.
SIDE VIEW