Fire Magic 327941 Installation Instruction

Page of 26
5
L-C2-378
REV 1 - 1407161000
TOP VIEW
(Countertop)
Lower support
Countertop 
overhang
Control
panel
ENCLOSURE
CUT-OUT
DIMENSIONS
Fig. 5-1
FRONT VIEW
B
C
D
See next page 
for substrate 
considerations
Countertop 
overhang
X
TOP VIEW
SIDE VIEW
Countertop 
overhang
(Control 
panel)
(Countertop)
Y
1
/
4
"
Clearance
(Overhang)
X= 
7
/
8
"
Y= Total     
     Countertop  
     Overhang
A
Control 
panel
Check 
clearance for 
control panel 
removal
MODEL SPECIFICATIONS TABLE
Table 1
32794 Series
Main burner BTU
N/P orifi ce drill size
15,000
#51/#58
Power supply rating
120VAC / 1.5A / 60 Hz
Non-combustible
enclosures
Combustible
enclosures
A  Countertop to unit bottom cut-out
12"
12"
B  Side to side cut-out
11-
1
/
2
"
12"
 Front to back cut-out
14"
14-
1
/
2
"
D  Control panel width cut-out
12-
5
/
8
"
12-
5
/
8
"
 The increased dimensions for combustible enclosures allow for a required air gap along 
the sides and rear of the unit. See the COMBUSTIBLE ENCLOSURE CUT-OUT section 
on the next page for details.
† Includes any substrate at front wall of enclosure (in the area the rear of the control panel 
is to sit fl ush against). See SUBSTRATE section on next page.
‡ Only applicable for enclosures that have countertops with an overhang (see illustration 
and section below).
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the enclosure countertop extends beyond the front wall, 
creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be created exposing 
the forward portions of the left and right side fi re walls of the unit. See illustrations above.
Important: 
FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and cross-
ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane tanks. See the 
ENCLOSURE REQUIREMENTS section for details.
MODEL SPECIFICATIONS