Viking RVER33015BBK Installation Instruction

Page of 28
42” min.
 
(106.7 cm)
13” max.
 
(
33.0 cm)
6” min.
(15.2 cm)
18” min.
(45.7 cm)
3/8”
 
(0.95 cm)
36” 
(
91.4 cm)
29-7/8”
(75.9 cm)
A
Range
Width
“A”
Dimension
30”
30” (76.2 cm)
Clearance Dimensions 
(Proximity to Cabinets)
8
• This range may be installed directly adjacent
to existing 36” (91.4 cm) high base cabinets.
IMPORTANT: The side trim MUST be 
3/8” (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using 
the adjustment spindles on the legs.
• The range CANNOT be installed directly
adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces
above 36” (91.4 cm) high. There must be
a minimum of 6” (15.2 cm) side clearance
from the range to such combustible surfaces
above the 36” (91.4 cm) counter height.
• Within the 6” (15.2 cm) side clearance to
combustible vertical surfaces above 
36” (91.4 cm), the maximum wall cabinet
depth must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm) side
clearance must be 18” (45.7 cm) above
the 36” (91.4 cm) high countertop.
• Wall cabinets above the range must be a
minimum of 42” (106.7 cm) above the
range cooking surface for the full width 
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
Note: If a range hood is installed, wall cabinets above the
range have a different minimum clearance height.
CAUTION
BURN HAZARD
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns. If cabinet
storage is used, the risk can be reduced 
by installing a rangehood that projects
horizontally a minimum 5
(12.7 cm) beyond
the bottom of cabinets.
CAUTION
To prevent possible damage to cabinets
and cabinet finishes, use only materials
and finishes that will not discolor or
delaminate and will withstand temperatures
up to 194°F (90°C). Heat and moisture
resistant adhesive must be used if the
product is to be installed in laminated
cabinetry. Check with your builder or
cabinet supplier to make sure that the
materials meet these requirements.