PRECAUTIONS TO BE 
OBSERVED BEFORE AND 
DURING SERVICING TO AVOID 
POSSIBLE EXPOSURE TO 
EXCESSIVE MICROWAVE 
ENERGY  
 
(a)  Do not operate or allow the oven to be operated with the door open. 
(b)  Make  the  following  safety  checks  on  all  ovens  to  be  serviced  before 
activating  the  magnetron  or  other  microwave  source,  and  make  repairs  as 
necessary:  interlock  operation,  proper  door  closing,  seal  and  sealing 
surfaces (arcing, wear, and other damage), damage to or loosening of hinges 
and latches, evidence of dropping or abuse). 
(c)  Before turning on microwave power for any service test or inspection within 
the  microwave  generating  compartment,  check  the  magnetron,  wave  guide 
or  transmission  line,  and  cavity  for  proper  alignment,  integrity  and 
connection. 
(d)  Any defective or misadjusted components in the interlock, monitor, door seal, 
and  microwave  generation  and  transmission  systems,  shall  be  repaired, 
replaced,  or  adjusted  by  procedures  described  in  this  manual  before  the 
oven is released to the owner. 
(e)  A  microwave  leakage  check,  to  verify  compliance  with  the  Federal 
Performance Standard, should be performed on each oven prior to release to 