Dacor RGC304SLPH Design Guide

Page of 2
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
4.12
RGC304, RGC365
30”, 36” Wide, Preference™ 
Renaissance Gas Cooktops
2/2
Revised
05/21/08
13" Max.
(330 mm)
A
3 1/8" Min.
(79 mm)
18" Min.
(457 mm)
30" Min.
(762 mm)
Clearances to Combustibles
1/4” (6 mm)
Mimimum clearance
to combustible
surfaces
Under Cabinet Clearances
Model
A: Minimum
A: Recommended
RGC304
30” (762 mm)
36” (914 mm)
RGC365
36” (914 mm)
42” (1067 mm)
Model
B: Minimum
RGC304
29” (737 mm)
RGC365
35 ¼” (895 mm)
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
RGC304 
RGC365
RGC304LP 
RGC365LP
Total Connected 
Load
0.25 Amps
(0.03 kW)
0.25 Amps
(0.03 kW)
Circuit 
Requirement
120 Vac,
60 Hz, 15 Amp
120 Vac,
60 Hz, 15 Amp
Gas Type
Natural
LPG
Manifold 
Pressure
5” Water Column
10” Water Column
Min. Gas Supply 
Pressure
6” Water Column
11” Water Column
Power Cord 
Length
40” (1016 mm)
10” (254 mm)
GAs AND ELECtRICAL REqUIREmENts*
* The data above is for reference only. If the above data does not 
agree with the product data label, use the data on the product data 
label.
Front of Unit
Data Label