Fisher & Paykel CG363MLDNGB1 Installation Instruction
PRODUCT & CUTOUT DIMENSIONS
CLEARANCE & CABINETRY DIMENSIONS
Product and cutout dimensions
(inches (mm))
C
G363ML
C
G363MLD
DEEP
A
overall height of product
(including retracted dials/pan supports)
3¾
”(96)
3¾
”(96)
B
overall width of product
35½
” (900)
35½
” (900)
C
overall depth of product
161⁄8
” (410)
207⁄8
” (530)
D
height of chassis
(below top of counter)
3½
” (89)
3½
” (89)
E
width of chassis
3311⁄16
” (856)
3311⁄16
” (856)
F
depth of chassis
151⁄8
” (384)
187⁄8
” (480)
G
depth of chassis
(including fi tted elbow*)
1611⁄16
” (424)
187⁄8
” (480)
H
overall width of cutout
341⁄16
” (865)
341⁄16
” (865)
I
overall depth of cutout
153⁄8
” (390)
197⁄16
” (494)
J
corner radius of cutout
max.
3⁄8
” (10)
max.
3⁄8
” (10)
K
distance from top of counter to center of gas inlet on product
2½
” (64)
2½
” (64)
L
distance from edge of chassis to gas inlet on product
¾
” (20)
¾
” (20)
* CG363ML models only: If countertop thickness exceeds 2” (50 mm), additional cutout space will be required to ac-
comodate the fi tted elbow.
comodate the fi tted elbow.
Installation diagrams for illustration purposes only
Note: Gas inlet connection is
located in the back left corner.
located in the back left corner.
Clearance and cabinetry dimensions
(inches (mm))
C
G363ML
C
G363MLD
DEEP
A
minimum clearance from left edge of product to nearest vertical surface
23⁄8
”(60)
23⁄8
”(60)
B
minimum clearance from right edge of product to nearest vertical surface
31⁄8
”(80)
31⁄8
”(80)
C
minimum clearance from rear edge of product to:
nearest combustible surface
nearest non-combustible surface (see
nearest combustible surface
nearest non-combustible surface (see
1
)
1¼
”(32)
less than
1¼
”(32)
½
”(13)
less than
½
”(13)
D
minimum distance from front edge of counter to front edge of product
1¼
”(32)
1¼
”(32)
E
minimum clearance from glass surface to combustible surface centered above
the cooking surface
the cooking surface
30
”(762)
30
”(762)
F
maximum overall depth of overhead cabinetry
13
”(330)
13
”(330)
G
minimum distance between overhead cabinets installed to either side of product
36
”(915)
36
”(915)
H
minimum vertical distance between counter and cabinet extending above the
counter
counter
18
”(457)
18
”(457)
I
minimum clearance below top of countertop to:
nearest combustible surface
Fisher & Paykel oven or nearest non-combustible surface
nearest combustible surface
Fisher & Paykel oven or nearest non-combustible surface
4½
”(115)
4
”(100)
4½
”(115)
4
”(100)
J
cutout measuring 2” x 20” (50 x 500mm) for air intake grill. Ensure air can easily enter the area around the base
of the product from the room in which the product is installed.
of the product from the room in which the product is installed.
Note: Ensure there is a grounded power outlet within 35½
” (900 mm) of the center rear of the product. A suitable fl exible hose
must be used between the product gas inlet and the connector on the wall. The connector should be 25½
”-29½
” (650 - 750mm)
above the fl oor and towards the left-hand end of the product. It should be accessible with the product installed.
A
B
I
J
H
C
G
D
E
F
2
3
A
B
C
E
D
F
H
I
J
K
L
G*
WARNING!
The CookSurface requires
adequate air supply to fully
function. The base of the
CookSurface must have direct
unrestricted ventilation to the
room where the CookSurface
is installed. Do not ventilate
the base area to an external
area that can be at different
air pressure to that of the
burners. You may ventilate
from adjacent cupboards, but
ensure that the available air
supply will not be restricted.
The ventilation area must be
20” x 2” (500 x 50 mm) or of an
equivalent area. If the 2” (50
mm) wide slot is not possible
due to the width of the
available toe recess, increase
the length of the slot so as to
maintain an equivalent area
of 100 in2 (250 cm2). An air
intake grill is provided. Ensure
that the grill is not covered or
obstructed.
adequate air supply to fully
function. The base of the
CookSurface must have direct
unrestricted ventilation to the
room where the CookSurface
is installed. Do not ventilate
the base area to an external
area that can be at different
air pressure to that of the
burners. You may ventilate
from adjacent cupboards, but
ensure that the available air
supply will not be restricted.
The ventilation area must be
20” x 2” (500 x 50 mm) or of an
equivalent area. If the 2” (50
mm) wide slot is not possible
due to the width of the
available toe recess, increase
the length of the slot so as to
maintain an equivalent area
of 100 in2 (250 cm2). An air
intake grill is provided. Ensure
that the grill is not covered or
obstructed.
Flush mounting