Vent-a-Hood BH346SLDSS Installation Instruction

Page of 6
Page 3
L108 0909A
36”
8’ Ceiling
24”-27”
12”
Custom
Enclosure
36”
8’ Ceiling
27”-30”
12”
Custom
Enclosure
Installation Details
1)  Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard liners only. 
Custom liners may require additional specification consideration.
2)  When installing a SLD wall mount liner (19 1/4” deep), it is recommended that the bottom edge of the liner be located no 
more than 24” - 27” from the cooking surface. For PSLD and PSLB wall mount liners (22 1/2” deep), it is recommended 
that the bottom edge of the liner be located no more than 27” - 30” from the cooking surface. For custom liners, the 
recommended height off the cooking surface is dependent on the depth of the liner. In general, the deeper the custom 
liner, the higher off the cooking surface it can be, up to a maximum recommended height of 30”. Exceeding recommended 
mounting height may compromise performance.
3)  Install the duct(s) from the outside of the home down to the location of the exhaust outlet(s) on the top of the liner 
allowing room for the transition (if applicable). If back venting, the elbow(s) should be installed so that the non-crimped 
end(s) are on the inside the collar(s) of the exhaust outlet(s). If a transition is used, install duct down to the location of 
the transition outlet plus 1”. This will allow the transition to engage 1” inside of duct. Consult the connection diagrams 
(next page) for further details on exhaust outlet placement.
 
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is included on the back 
page of this instruction sheet.
 
Transition heights are as follows:
 
Single Blower (B100): 
6” round duct will connect directly to the top of the liner.
Dual Blower (B200): 
8” round duct will connect directly to the top of the liner.
Single and Dual Blower (B100 & B200): 
6” round duct will connect directly to the top of the hood; 8” round will 
connect directly to the top of the hood. Optional 10” round combination 
transition (VP562, sold separately) is 17 1/2”  tall.
Two Dual Blowers (Two B200s): 
Two 8” rounds connect directly to the top of the hood. Optional 12” round 
combination transition (VP563, sold separately) is 16 1/2” tall.
SLD Liner
PSLD/PSLB Liner