English 11
Prepare holes at fastener locations as identified below:
For walls, wall studs, or floors composed of solid 
wood or metal, drill 1/8" pilot holes.
For walls or floors composed of drywall, sheet-rock 
or other soft materials, drill 3/16" holes to a mini-
mum depth of 1-3/4", then tap plastic anchors into 
each of the holes using a hammer.
For walls or floors composed of concrete or con-
crete block, drill 3/16" holes to a minimum depth of 
1-3/4", then tap concrete anchors into each of the 
holes using a hammer.
For walls or floors having ceramic tile covering, drill 
3/16" holes through the tile only, then drill into the 
material behind the tile as indicated immediately 
above.
If the range is moved to a new location, the Anti-Tip 
Device must be removed and reinstalled.
Mounting Anti-Tip Bracket
The alternative floor mounted bracket shall be installed as 
follows:
1. Place bracket on floor in position shown in Figure 7 
(Bracket may be used in either corner of the installation 
area).
2. Secure to floor or wall stud.
3. Later, when the unit is installed, the adjustable leg will 
slide under the bracket.
 Figure 6: Anti-tip Bracket
 Figure 7: Placement of Anti-Tip Bracket (Top View)
X
from edge of range
X
typical -
either side
Wall Line
Floor
Right
Cabinet
Front Edge of
Right Cabinet
Left
Cabinet
X = 4-1/2” (for 30” range)
X = 6-3/4” (for 36” range)