  GENERAL
• Carefully read the following important information regarding installation
safety and maintenance. Keep this information booklet accessible for further
consultations. 
 POWER SUPPLY CONNECTION
For connection to the power supply refer to the following:
1. Open the fl ap Fig.16
2. Remove the power supply cover by undoing 
the (2) screws Fig. 17.
3. Connect the wires of the hood to those of 
the power supply as described. Fig.18 :  
BLACK =  L line
WHITE =  N neutral
GREEN / YELLOW =   G ground
- A double-pole switch properly rated must  
be installed to provide the range hood 
power supply disconnection.
- Connect the electrical conduit to the Field 
Wiring Compartment using listed  conduit 
fi ttings.
- Carry out the power supplly connection in 
accordance with the national electric code, 
ANSI/NFPA 70-1999.
4.  Insert the wires into the box, then close the 
box cover, securing it using the screws that 
were previously removed.
5. Close the fl ap until it clicks into place. 
- 19 -