Hotpoint RA720K Dimensional Illustrations

Page of 2
420510
Specification Revised 11/06
RA720K – Hotpoint 20" Free-Standing Electric Range
Dimensions (in inches)
Listed by 
Underwriters 
Laboratories
All GE ranges are equipped with 
an Anti-Tip device. The installation 
of this device is an important, 
required step in the installation  
of the range.
 KW Rating
240V
9.2
 208V
6.9
From combustible
walls above
cooking surface
C
36
13"
MAX
36" MAX
40-1/2
5
2
2-1/2
30" MIN
15" MIN
Surface
mount
outlet
(Depth with
 door open)
B
D
A
Receptacle locations
Locally approved flexible service cord or  
conduit must be used because terminals are 
not accessible after range installation. See 
shaded area in drawings for location of  
electrical outlet box. Recommended outlet 
locations allow range to be installed directly 
against rear wall.
Recommended acceptable electrical
outlet area. Orient the electrical
receptacle so the length is parallel
to the floor.
Floor
Outlet box
Cord
Wall Mounted
Wall
2-1/4"
Models
A
B
C
(recommended)
D
20" Wide
20"
20-3/8"
2"
41"
24" Wide
24"
24-3/8"
2"
41"