Monogram ZGP364NDRSS Specification Sheet

Page of 3
For answers to your Monogram,
® 
GE Profile
 or 
GE
®
 appliance questions, visit our website at 
geappliances.com or call GE Answer Center
®
 
service, 800.626.2000.
130561
Specification Revised 4/11
Listed by 
Underwriters 
Laboratories
ZGP364NDRSS (Natural Gas)
ZGP364LDRSS (Liquid Propane)
GE Monogram
® 
36" All-Gas Professional Range with 4 Burners and Griddle
Dimensions and Installation Information (in inches) 
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical 
combustible surface at the rear. A backsplash is required 
for installations with less than 12" clearance. The following 
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order one with a 36"-wide range backsplash 
ZX12B36PSS–12" backsplash
ZXADJB36PSS– 30"-36" adjustable-height backsplash with 
warming shelf
Side View with a Backsplash
Electrical Requirements
Ranges must be hooked up to a 120V, 60Hz properly 
grounded dedicated circuit protected by a 15-amp circuit 
breaker or time-delay fuse.
Universal Utility Locations
4-5/8”
13-3/8”
36”
11-3/8”
2”
2”
6-1/2”
Gas/
Electric
Gas/
Electric
Locate gas and  
electric as shown
10-1/2”
1-1/2”
12”
28-1/4” to
Beveled 
Edge of Control
Panel Bullnose
27-1/2” to
Beveled Edge
- Maximum
Adjacent
Cabinet Depth
for
Flush
Installation
13/16”
30-36”
3-3/16”
Control Panel
Depth
28-1/4”
to Front of
Door
48-1/4”
with Oven Door
Open
31-1/16”
to Front of
Handle
35-1/4”
to
36-3/4”
7” Control
Panel Height
28-7/8”
to Front
Edge
Optional
Backsplash
Accessories
Gas Supply
•  The natural gas models are designed to 
operate at 5" water column pressure. 
For proper operation, the pressure of 
the natural gas supplied to the regulator 
must be between 7" and 13" water 
column.
•  The LP models are designed to operate 
at 10" water column pressure. For 
proper operation, the pressure of the LP 
gas supplied to the regulator must be 
between 11" and 13" water column.
Universal Utility Locations