Dacor DCT305SLPH Installation Instruction

Page of 16
5
Cabinet and Countertop Layout
 WARNING
•  Failure to meet or exceed the maximum and minimum 
dimensions/clearances stated in these instructions 
may result in a fire hazard.
•  Follow the countertop manufacturer’s instructions 
regarding the minimum corner radius, use of heat 
reflective tape, reinforcement of corners, etc.
•  Carefully check the location where the cooktop will be 
installed. For best performance, the cooktop should be 
placed away from drafts that may be caused by doors, 
windows and heating and air conditioning outlets. 
•  This appliance is to be used in conjunction with a suit-
able vent hood or approved Dacor raised vent system.
Model
(A) Minimum
(A) Recommended
DCT305
30” (76.2 cm)
36” (91.4 cm)
DCT365
36” (91.4 cm)
42” (106.7 cm)
Installation Specifications
•  Allow a minimum 1/4” (6 mm) clearance between the 
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed 
below the cooktop.
Model
(B) Minimum
DCT305
29 1/4” (74.3 cm)
DCT365
35 1/4” (89.5 cm)
Under Cabinet Clearances
•  The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so that they do not inter-
fere with the cooktop when it is installed. If installing 
another appliance in the cabinet below, allow for the 
routing of gas and electrical service behind it.
The installation must allow for the following:
•  Access to the gas shut-off valve and regulator when 
the unit is installed. 
•  Access to the electrical outlet when the cooktop is in 
place. The 42” (106.7 cm) power cord must be able to 
reach the electrical outlet.
•  Access to the underside of the cooktop for service and 
inspection purposes.
•  Clearance inside the cabinet to allow for proper hold 
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed 
shelf should not be installed below the cooktop. See the fol-
lowing pages for countertop cutout dimensions.
Raised Vent Compatibility
Model DCT305 is not compatible with a raised vent. If 
installing cooktop model DCT365 with a raised vent, install 
only Dacor raised vent model ERV3615. Installation of any 
other raised vent model may cause improper operation.
1/4” (6 mm)
mimimum clearance
to combustible
surfaces
 B
 * Allows for clearance between hold down brackets
13” max.
3
(33.0 cm)
3
 This specification does not apply for 
cabinets located 
   greater than a horizontal distance of 
 
5 1/2” (14.0 cm) from
   edge of cooktop. Allow 6 7/8” (17.5 cm) 
 
from cutout edge.
A
 1 5/8” min. 
(4.1 cm)
Combustible 
surface to rear
30” min.
1, 2
(76.2 cm)
See cutout
dimensions
See cutout
dimensions
2
 If installing with an overhead range hood, check the hood 
  
 
specifications for minimum required clearances.
1
 Distance to combustible surfaces measured from cooking 
   surface (top of cooktop grate).
  18” min.
1, 3
(45.7 cm)
All tolerances +1/16” (+1.6 mm), -0 
unless otherwise noted.
Minimum Required Clearances Around the Cooktop