Gaggenau AL400721 Brochure
Ventilation appliances
215
A W 280 190
Stainless steel
Width 90 cm
Air extraction/recirculation
Width 90 cm
Air extraction/recirculation
A W 280 120
Stainless steel
Width 120 cm
Air extraction/recirculation
Width 120 cm
Air extraction/recirculation
A W 281 190
Aluminium-lacquered
Width 90 cm
Air extraction/recirculation
Width 90 cm
Air extraction/recirculation
A W 281 120
Aluminium-lacquered
Width 120 cm
Air extraction/recirculation
Width 120 cm
Air extraction/recirculation
Necessary installation accessories
A D 280 012
A D 280 012
Exhaust air duct stainless steel, for
ceiling heights 2.25 m - 2.62 m
ceiling heights 2.25 m - 2.62 m
A D 280 022
Exhaust air duct stainless steel, for
ceiling heights 2.62 m - 3.01 m
ceiling heights 2.62 m - 3.01 m
A D 281 012
Exhaust air duct aluminium-lacquered,
for ceiling heights 2.25 m - 2.62 m
for ceiling heights 2.25 m - 2.62 m
A D 281 022
Exhaust air duct aluminium-lacquered,
for ceiling heights 2.62 m - 3.01 m
for ceiling heights 2.62 m - 3.01 m
Air recirculation duct for ceiling
heigths including air flow in the duct
(order activated charcoal filter
separately)
A D 280 112
heigths including air flow in the duct
(order activated charcoal filter
separately)
A D 280 112
Recirculating air duct stainless steel
for ceiling heights 2.36 m - 2.62 m
for ceiling heights 2.36 m - 2.62 m
A D 280 122
Recirculating air duct stainless steel
for ceiling heights 2.62 m - 3.01 m
for ceiling heights 2.62 m - 3.01 m
A D 281 112
Recirculating air duct aluminium-
lacquered for ceiling heights
2.36 m - 2.62 m
lacquered for ceiling heights
2.36 m - 2.62 m
A D 281 122
Recirculating air duct aluminium-
lacquered for ceiling heights
2.62 m - 3.01 m
lacquered for ceiling heights
2.62 m - 3.01 m
A D 010 392
Ceiling collar for air ducts
Stainless steel
Stainless steel
A D 011 392
Ceiling collar for air ducts
Aluminium-lacquered
Aluminium-lacquered
Special accessories
K F 001 010
K F 001 010
Activated charcoal filter
Side duct, special ducts
made to measure. For production
reasons, aluminium-lacquered ducts
have a longer delivery time.
reasons, aluminium-lacquered ducts
have a longer delivery time.
Please enquire about price.
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Wall-mounted hood
A W 280/A W 281
– Coanda effect leads to highly
efficient extraction, even on lowest
power level
power level
– Reduced energy consumption and
less noise
– Air extraction or recirculation
system
– Dimmable Soft-Light
Output
Performance and noise level, output
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
Appliance width 90 cm
Air extraction:
440 / 600 m³/h + Coanda effect
80 / 80 m³/h.
61 / 69 dB (A) re 1 pW.
47 / 54 dB (A) re 20 μPa.
Air recirculation:
250 / 300 m³/h + Coanda effect
100 / 100 m³/h.
70 / 72 dB (A) re 1 pW.
56 / 60 dB (A) re 20 μPa.
Air extraction:
440 / 600 m³/h + Coanda effect
80 / 80 m³/h.
61 / 69 dB (A) re 1 pW.
47 / 54 dB (A) re 20 μPa.
Air recirculation:
250 / 300 m³/h + Coanda effect
100 / 100 m³/h.
70 / 72 dB (A) re 1 pW.
56 / 60 dB (A) re 20 μPa.
Appliance width 120 cm
Air extraction:
450 / 610 m³/h + Coanda effect
80 / 80 m³/h.
61 / 69 dB (A) re 1 pW.
47 / 54 dB (A) re 20 μPa.
Air recirculation:
250 / 300 m³/h + Coanda effect
100 / 100 m³/h.
70 / 72 dB (A) re 1 pW.
56 / 60 dB (A) re 20 μPa.
Air extraction:
450 / 610 m³/h + Coanda effect
80 / 80 m³/h.
61 / 69 dB (A) re 1 pW.
47 / 54 dB (A) re 20 μPa.
Air recirculation:
250 / 300 m³/h + Coanda effect
100 / 100 m³/h.
70 / 72 dB (A) re 1 pW.
56 / 60 dB (A) re 20 μPa.
Features
3 electronically controlled output
levels.
Intensive mode with ongoing Coanda
effect.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Fully illuminated surface with compact
fluorescent tube 2 x 36 W and
dimmable Soft-Light.
levels.
Intensive mode with ongoing Coanda
effect.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Fully illuminated surface with compact
fluorescent tube 2 x 36 W and
dimmable Soft-Light.
Planning notes
For calculating the exhaust air line go
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
A large drop in output and significantly
increased noise can be expected in the
air recirculation mode in the case of
ventilation hoods with a very high air
output.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
70 cm.
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
A large drop in output and significantly
increased noise can be expected in the
air recirculation mode in the case of
ventilation hoods with a very high air
output.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
70 cm.
Clearance above electric appliances
min. 60 cm.
Side outlet possible no lower than
58 cm from the bottom edge of the
hood (pipe middle).
Fit the socket concealed behind
ventilation duct.
Weight 29 – 35 kg.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4016,
ground and brushed IIIC.
Recommendation for aluminium parts
to match hood: RAL 9006 white-
aluminium or request a paint sample.
The dimensions of the air ducts refer to
a distance of 1.60 m from the floor to
the bottom edge of the hood.
Convert for other installation heights:
Worktop height + minimum clearance
+ hood with duct.
min. 60 cm.
Side outlet possible no lower than
58 cm from the bottom edge of the
hood (pipe middle).
Fit the socket concealed behind
ventilation duct.
Weight 29 – 35 kg.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4016,
ground and brushed IIIC.
Recommendation for aluminium parts
to match hood: RAL 9006 white-
aluminium or request a paint sample.
The dimensions of the air ducts refer to
a distance of 1.60 m from the floor to
the bottom edge of the hood.
Convert for other installation heights:
Worktop height + minimum clearance
+ hood with duct.
Connection
Total connected load 295/295 W .
Connecting cable 1.4 m with plug.
Connecting cable 1.4 m with plug.