GTX65EBSJ
GE
®
Series 6.1 Cu. Ft. Capacity Aluminized Alloy Drum Electric Dryer with HE Sensor Dry
For answers to your Monogram, GE Profile
™
Series
or GE
®
Series appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
22 1/2"
27 3/4"
26"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
Power Cord 4 1/2"
11 3/4"
Side View
Rear View
5.7 cu. ft. Dryers
2
Back View
Power
Cord Hole
30-1/2
5.8, 6.0 and 7.0 cu. ft. Dryers
5
Back View
Power
Cord Hole
4-1/2
Power Cord LoCations
BaCk View
side View
rear View
eLeCtriC dryer rating:
240V
5600W
24A
60Hz
208V
4400W
22A
60Hz
exhaust oPtion: 4-way rear, right, left and bottom.
CirCuit requirements: An individual, properly-grounded branch circuit,
CirCuit requirements: An individual, properly-grounded branch circuit,
protected by a 30-amp circuit breaker or a time-delay fuse, is required.
note: Dryer wall outlet must be located within 36" of service cord entry and
note: Dryer wall outlet must be located within 36" of service cord entry and
acessible when dryer is mounted in position.
instaLLation information: For complete information, see installation
instaLLation information: For complete information, see installation
instructions packed with your dryer.
dimensions and instaLLation information (in inChes)
sPeCiaL instaLLation requirements
aLCoVe or CLoset instaLLation:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 3"
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 3"
front and rear.
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.
of open area equally distributed. If this closet contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom instaLLation:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
Bathroom or Bedroom instaLLation:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
minimum CLearanCes other than aLCoVe or CLoset instaLLation:
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear.
dryer exhausting information :
- Use metal duct only, vertical and horizontal ducting.
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear.
dryer exhausting information :
- Use metal duct only, vertical and horizontal ducting.