Amana PTC093G25AXXX Specification Sheet
SS-DPTAC www.amana-ptac.com
7
6
www.amana-ptac.com SS-DPTAC
P
roduCT
s
PeCifiCATions
P
roduCT
s
PeCifiCATions
P
roduCT
s
PeCifiCATions
: PTH m
odels
— r
everse
-C
yCle
H
eATing
P
erformAnCe
Notes:
¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
² Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
³ Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
² Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
³ Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
Minimum voltage on 265-volt models is 238.5 volts; maximum is 291.5 volts.
⁴ Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay
fuses (included and factory-installed on all Amana® brand 265-volt chassis). See heater performance for total MCA.
⁵ Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat
at approximately 24°F outdoor ambient.
⁶ Total watts for 12,000 and 15,000 BTU/h models; subtract 70 watts for PT07/09*E**A*
⁷ Specify two-digit heater kW size to complete model number.
⁸ Total amps for 12,000 and 15,000 BTU/h models; subtract 0.2 amps for PT07/09*E*A*.
⁹ R-410A refrigerant used in all systems.
¹⁰ All units meet or exceed ASHRAE 90.1 standards.
¹¹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹² Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
⁷ Specify two-digit heater kW size to complete model number.
⁸ Total amps for 12,000 and 15,000 BTU/h models; subtract 0.2 amps for PT07/09*E*A*.
⁹ R-410A refrigerant used in all systems.
¹⁰ All units meet or exceed ASHRAE 90.1 standards.
¹¹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹² Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
230/208 V
olts
Heating Capacity ¹
PTH
073E**AXXX
PTH
093E**AXXX
PTH
123E**AXXX
PTH
153E**AXXX
Voltage ¹
,
³
230 / 208
230 / 208
230 / 208
230 / 208
BTU/h
⁵
6,800 / 6,800
8,300 / 8,100
10,900 / 10,500
13,500 / 13,300
Amps
¹²
3.5 / 3.5
4.1 / 4.1
5.6 / 5.6
7.0 / 7.0
Watts
¹²
605 / 605
735 / 720
1040 /1020
1365 / 1345
COP
5
3.3 / 3.3
3.3 / 3.3
3.1 / 3.1
2.9 / 2.9
CFM (Dry)
310
310
310
360
265/277 V
olts
Heating Capacity ¹
PTH
074E**AXXX
PTH
094E**AXXX
PTH
124E**AXXX
PTH
154E**AXXX
Voltage ¹
,
³
265
265
265
265
BTU/h
⁵
6,800
8,200
11,000
13,500
Amps
¹²
3.0
3.6
4.8
6.0
Watts
¹²
585
730
1040
1365
COP
⁵
3.4
3.3
3.1
2.9
CFM (Dry)
310
310
310
360
COP = Coefficiency of Performance; per ARI test procedures, units are rated for capacities and efficiencies.