Fire Magic 32881P Installation Instruction

Page of 12
TABLE OF CONTENTS
PRODUCT DATA TABLE
SAFETY WARNINGS & CODES 
1
TABLE OF CONTENTS 
3
CAUTION 
3
PRODUCT DATA TABLE 
3
PARTS LIST 
4
PLANNING FOR INSTALLATION OF THE SEARING STATION 
4
WHERE TO INSTALL THE SEARING STATION 
4
ENSURING PROPER COMBUSTION AIR AND COOLING AIRFLOW 
4
INSTALLATION 
5
GAS-SUPPLY PLUMBING REQUIREMENTS 
5
CHECKING FUEL AND ORIFICES 
5
CONVERTING THE SEARING STATION REGULATOR 
6
CONNECTING THE GAS SUPPLY TO THE SEARING STATION 
6
LEAK TESTING 
6
GENERAL INFORMATION 
7
SAFETY TIPS IN USING THE SEARING STATION 
7
CARE AND CLEANING 
7
FLAME PATTERN 
7
SEARING STATION FLAME PATTERN 
7
SAFE USE & MAINTENANCE OF PROPANE-GAS CYLINDERS 
9
LIGHTING (IGNITION) INSTRUCTIONS 
11
ELECTRONIC LIGHTING 
11
MANUAL LIGHTING 
11
FIRE MAGIC
®
 OUTDOOR GAS GRILL LIMITED WARRANTY  
12
CAUTION
Table 1 - Product data table
*
Note:  If using an insulating liner, 
consult liner instructions for 
counter cut-out dimensions. 
Height
Width
Depth
Fig. 3-1
Do not strike or scrape the ceramic portion of the burner(s) with hard tools, as the material may crack, 
chip, or break. Prevent any grease, water, or other foreign material from getting into the ceramic portion of 
the burner(s), especially when cold. Always wait for the burner(s) to heat up to a well-distributed red glow 
before placing food on the cooking grid. When a burner is hot, it will vaporize small amounts of grease 
that drip on it. Always cover the burner(s) when not in use. Keeping the ceramic portion of the burner(s) 
free of foreign substances will allow the gas to circulate and burn over the entire heating surface, allowing 
for powerful and even cooking over the life of the burner(s). 
3
L-C2-342
Rev 0 - 1009230737
Specifi cation
Value
Counter opening height*
12"
Counter opening width*
19"
Counter opening depth*
18-
3/
4
"
Main burner
BTU per burner
16,000
Natural-gas orifi ce
#46
Propane-gas orifi ce
#56