Asko D5636XLHSPH Installation Instruction

Page of 16
10
11
If the cord is not long enough, or if a hard-wire installation 
is needed, follow the steps below to complete the 
electrical connection.
WARNING!
Before starting this procedure, be sure the power is 
turned off at the breaker/fuse box.
4.   Connect ground wire to ground connection screw 
on the bottom.
NOTE:
When doing a hard-wire installation, you must remove 
the supplied power cord.
TESTING FOR LEAKS
1.  Turn on the water supply and check for leaks.
2.  Turn the power on at breaker/fuse box and test the 
dishwasher operation by running a Rinse & Hold 
cycle. (This should take about six minutes.)
3.  Turn off the electrical power and check for leaks 
under the dishwasher and sink. 
4.  Make sure that no kinks have developed in the drain 
lines.
  If there are no leaks and the dishwasher seems to 
be working properly, continue with the installation.
In order to prevent heat damage to the inlet valve, all 
solder connections must be made before the water 
supply line is connected.
Flush the water supply line prior to connecting it to the 
water fill tube. 
The unit has a float switch in the base pan to protect 
against flooding. If the inlet valve connection is not 
seated properly, water may leak into the base pan and 
activate the float switch. 
Water connection should be carried out by a qualified 
professional. It is important that the water supply line 
and the shut-off valve have a sufficient flow volume. At 
least 3 gallons (12 liters) per minute must be able to 
pass through the line. Connect the machine using the 
accompanying supply hose. Water pressure should be 
4.2-140 PSI. There should be a shut off valve on the 
water pipe. 
If the pipes are newly installed, it may be wise to flush 
them through so that any debris is washed away. 
Otherwise, debris can clog the filter in the machine’s 
water intake and cut off the water supply.
Only use the inlet hose supplied with the machine. Do 
not reuse old or other loose inlet hoses.
Use the supplied O ring and tighten the connection by 
hand plus a quarter turn with a wrench.
NOTE:
Be sure to run the PEX tubing through the hole leading 
to the sink compartment before moving the dishwasher 
into position.
1.  Connect supply cable with 
a UL-listed strain relief 
bushing (if nonmetallic 
cable is to be used).
2.   Connect branch circuit 
white lead to N lead on 
filter.
3.   Connect branch circuit 
black lead to L lead on filter.
CONNECTING THE ELECTRIC CABLE
CONNECTING THE WATER SUPPLY
1. Water supply
2. Water supply valve to dishwasher (not supplied)
CUSTOMER CARE CENTER 1-800-898-1879 • WWW.ASKONA.COM
CUSTOMER CARE CENTER 1-800-898-1879 • WWW.ASKONA.COM
492169 Install DW16 USA EN Rev 01.indd   11
2015-01-13   11:12:49