GE GTD42EASJWW Specification Guide

Page of 3
Listed by 
Underwriters 
Laboratories
For answers to your Monogram,
® 
Cafe
 Series, 
Profile
 Series or GE
®
 appliance questions, visit 
our website at geappliances.com or call  
GE Answer Center
®
 service, 800.626.2000.
GTD42EASJ 
GE
®
 7.2 cu. ft. capacity electric dryer
5.7 cu. ft. Dryers
2
Back View
Power 
Cord Hole
30-1/2
5.8, 6.0 and 7.0 cu. ft. Dryers
5
Back View
Power 
Cord Hole
4-1/2
Power Cord Locations
Electric Dryer Rating:
240V
5600W
24A
60Hz
208V
4400W
22A
60Hz
Exhaust Option: 4-way rear, right, left and bottom
Circuit Requirements:  An individual, properly-grounded branch circuit, 
protected by a 30-amp circuit breaker or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36" of service cord entry 
and acessible when dryer is mounted in position.
Installation Information: For complete information, see installation 
instructions packed with your dryer.
Dimensions and Installation Information (in inches)
Specification Created 3/15
Special Installation Requirements
Alcove or Closet Installation:
 
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label  
  on the dryer back. 
• The dryer MUST be exhausted to the outside. 
•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 
0" either side; 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. 
•  Closet doors must be louvered or otherwise ventilated and must contain a minimum 
of 60 sq. in. of open area equally distributed. If this closet contains both a washer and 
a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors. 
•  The installation must conform with the local codes, or in the absence of local codes, 
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
•  Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.