Components and measurement values
Item 
number
Component
Measurement value
Comment
80 658 33
CIM motor
Resistances: 
Pins 1-3 stator 3.7 Ω
Pins 1-2 stator 3.6 Ω
Pins 2-3 rotor 3.6 Ω
Pins 4-5 tacho 178 Ω
80 617 03 
80 617 04
Heating element 2000 

Heating element 1000 
W
80 761 02
Thermistor
6.1–3.8 kΩ (at room 
temperature 20–30°C)
The thermistor for measuring temperature 
is located between the motor cradle and the 
drum. The thermistor measures and controls 
the water temperature, which can vary from 
0 to 92°C. The heater is disconnected if the 
thermistor is short-circuited or disconnected 
from the programme control card.
88 012 63
Drainage pump 50 Hz
144 Ω
The drainage pump is combined with an 
integrated fine filter trap, which can be cleaned 
by the user. If the drainage pump has run for 3 
minutes during draining, the programme stops, 
resets and a fault code is indicated on the display. 
The pump has a capacity of 20 litres/minute.
88 012 64
Drainage pump 60 Hz
76 Ω
80 782 21
Level switch
Electromechanical level switch with two levels 
(see wiring diagram). Used to indicate levels for 
door opening, heat and overflow.   
80 762 02
EMC filter 50/60 Hz
680 Ω
The filter eliminates interference to and from 
the machine.
80 793 24
Inlet valve
3.7 kΩ ± 0.5 kΩ
Two-way inlet valve, 8 litres/minute
80 798 73
Door lock
122 Ω
The door lock is electromechanical and 
equipped with a magnet.
80 833 15
One-way inlet valve
80 818 07
Motor control
80 806 28 Control unit
80 833 43
Communication unit
80 083 65 Outlet valve