Electrolux EI36EC45KS Installation Instruction

Page of 20
2
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
I
H
G
A
Figure 2 – COUNTERTOP CUTOUT OPENING
CAUTION
To eliminate the risk of burns or
fire by reaching over heated surfaces, cabinet
storage space located above the cooktop should
be avoided. If cabinet storage is provided, risk
can be reduced by installing a range hood that
projects horizontally a minimum of 5” (12.7 cm)
beyond the bottom of the cabinets.
Letters on this figure refer to chart on front page except for J , K & L.
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13” (33 cm)
30” (76.2 cm) Min.
Clearance Between the
Top of the Cooking
Platform and the Bottom
of an Unprotected Wood
or Metal Cabinet.
24” (61 cm) Min. when
Bottom of Wood or Metal
Cabinet is Protected by
Not Less Than 1/8” (0.3 
cm) Flame Retardant 
Millboard Covered With
Not Less Than No. 28 
MGS Sheet Steel, 0.015”
(0.4 mm) Stainless 
Steel, 0.024” (0.6 mm)
Aluminum or 0.020” (0.5
mm) Copper.
2 1/2” (6.4 cm) Min. From Edge
of Cutout to Front Edge of
Countertop
18”
(45.7 cm)
J
 
Min. From Edge of
Cooktop to Nearest 
Combustible Wall
(Either Side of Unit).
12”
(30.5 cm)
10”
( 25.4 cm)
K
Min. Recommended
Distance Between Rear
Edge of Cutout and
Nearest Combustible
Surface Above
Countertop
24”
(61 cm)
Install junction box at a
location which will be easy
to reach and that will not
interfere with the cooktop
installation. We suggest
12” (30.48cm) lower than
the countertop.
If a drawer is present
underneath, allow at least
10” (25.4cm) of clearance
below the countertop.
CAUTION
 Never store 
flammable products in the
drawer.
L
Min.
MODEL
J
K
L
30’’ (76.2 cm)
2’’ (5.1 cm)
2’’ (5.1 cm)
30’’ (72.6 cm)
36’’ (91.4 cm) 
2’’ (5.1 cm)
2’’ (5.1 cm)
36’’ (91.4 cm)