Premium PIA12067B Owner's Manual

Page of 58
INSTALLATION MANUAL Installation of the Indoor unit 
3
2
1
The piping  can  be  run  in the 3 directions indicated by
numbers  in  the  picture. When  the  piping  is  run  in 
direction 1 or 3, cut a notch along the groove on the side 
of the indoor unit with a cutter.
Run the piping in the direction of the wall hole and bind 
the  copper  pipes, the  drain pipe and the  power cables 
together with the tape with the drain pipe at the bottom, 
so that water can flow freely.
 Do not remove the cap  from the pipe until connecting 
     it, to avoid dampness or dirt from entering.
 If the pipe is bent or pulled  many times, it  will become 
     stiff. Do  not  bend  the pipe more than three times at 
     one point.
 When extending the rolled pipe, straighten the pipe by 
     unwinding it gently as shown in the picture.
    1.   Remove the indoor unit pipe cap (check that there is 
          no debris inside).
    2.   Insert  the flare nut and create a flange at the extreme 
          end of the connection pipe.
    3.   Tighten  the  connections  by  using  two  wrenches 
          working in opposite directions
torque wrench
Connecting the pipes
Indoor unit condensed water drainage
The indoor unit condensed water drainage is fundamen-
tal for the success of the installation.
1. Place the drain hose below the piping, taking care not 
    to create siphons.
2. The drain hose must slant downwards to aid drainage. 
3. Do not bend the drain hose or  leave  it  protruding or 
    twisted and do not put the end  of  it in water.  If  an 
    extension is connected to the drain hose, ensure that 
    it is lagged when it passes into the indoor unit.
4. If the piping is installed to the right, the pipes,  power 
    cable and drain hose must be lagged and secured onto 
    the rear of the unit with a pipe connection. 
1) Insert the pipe connection into the relative slot. 
2) Press to join the pipe connection to the base.  
YES
18
Refrigerant piping connection
Connections to the indoor unit
NO
NO
NO
YES
Extending the rolled pipe
Shape the connection pipe