INSTALLATION MANUAL Installation of the outdoor unit 
The air and humidity left inside  the refrigerant circulat-
ion can cause compressor malfunction. After having co-
nnected the indoor  and outdoor units, bleed  the air and 
humidity  from  the  refrigerant  circulation  using  a va-
cuum pump. 
Refrigerant flow direction
2-way valve
(6) Open 1/4 turn
valve cap
(1) Turn
(8) Tighten
(2) Turn
3-way valve
(8) Tighten
(1) Turn
(7) Turn to fully
      open the valve
(7) Turn to fully 
      open the valve
(8) Tighten
Service 
port nut
Valve cap
(1) Unscrew and remove the caps from the  2 - way and 
      3-way valves. 
(2) Unscrew and  remove  the cap from the service port.
(3) Connect  the  vacuum pump hose to the service port.
(4) Operate the vacuum pump for  10 - 15  minutes until 
      an absolute vacuum of 10 mm Hg has been reached. 
(5) With the vacuum pump still in operation,  close the 
      low - pressure  knob on the vacuum pump coupling. 
      Stop the vacuum pump. 
(6) Open the 2 - way valve by 1/4  turn and then close it 
      after 10 seconds. Check all the joints for leaks using 
      liquid soap or an electronic leak device. 
(7) Turn the body of the 2-way and 3-way valves. 
      Disconnect the vacuum pump hose. 
(8) Replace and tighten all the caps on the valves. 
3-way valve diagram
connect to indoor unit
open position
spindle
service port cap
Connect to 
outdoor unit
Valve core
needle
INSTALLATION MANUAL final stages 
wall
(indoor)
(outdoor)
piping
piping
gasket
insulating tape
insulating covering
Clamps
1. Wind insulating covering around the joints of the ind-
    oor unit and fix it with insulating tape.
2. Fix  the  exceeding  part  of  the  signal  cable  to  the 
    piping or to the outdoor unit.
3. Fix the piping to the wall ( after having coated it with
    insulating tape) using clamps or insert  them into pla-
    stic slots.
4. Seal the hole  in  the wall through which the piping is
    passed so that no air or water can fill.
 Do the ON/OFF and FAN  operate normally?
 Does the MODE  operate normally?
 Do the set point and TIMER function operate properly?
 Does each lamp light normally?
 Do the flap  for air flow direction operate normally?
 Is the condensed water drained regularly? 
 Is  there  any  abnormal  noise  or  vibration  during 
     operation?
 Could the noise,  the air flow or the condensed water 
     drainage disturb the neighbours?
 Is there any coolant leakage?
Indoor unit test
Outdoor unit test
Note: the electronic controller allows the compressor to 
         start  only  three  minutes  after voltage has reached 
         the system.
21
BLEEDING
Indoor unit