During  the installation of the indoor and outd-
oor units the access to the working area should 
be forbidden to children.
Unforeseeable accidents could happen.
Make sure that  the base of  the outdoor unit  is
firmly fixed.
Check that air  cannot enter the refrigerant sys- 
tem and check for  refrigerant leaks when  mo-
ving the air conditioner. 
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER 
Carry out a test cycle after installing the 
air conditioner and record the operating data. 
inverter
The ratings of the fuse installed in the built-in
control unit are  T 5A /  250V. 
The user must  protect  the  indoor unit  with a 
fuse of  suitable capacity for the maximum  in-
put current or with another overload protection
device. 
Ensure that  the mains voltage corresponds  to 
that stamped on the rating plate. Keep the sw-
itch or power plug clean. Insert the power plug 
correctly and firmly into the socket, thereby a- 
voiding the risk of electric shock or fire due to 
insufficient contact. 
Check that the socket  is suitable for the plug, 
otherwise have the socket changed. 
Do not install the appliance at  a  distance  of 
less than 50 cm from inflammable substances 
(alcohol, etc.) Or from pressurised containers 
(e.g. spray cans). 
If  the appliance  is used  in areas without the 
possibility of ventilation, precautions must be 
taken to prevent any leaks  of refrigerant  gas
from remaining in the environment and creat-
ing a danger of fire. 
The packaging materials  are  recyclable  and 
should  be  disposed  of  in the separate waste 
bins.Take the 
air conditioner at the end 
of  its useful life to a special  waste collection 
centre for disposal. 
inverter 
Only use the 
air conditioner  as  
instructed  in this booklet. These instructions 
are not intended  to cover  every  possible  
condition  and situation. As  with  any electrical  
household appliance,  common  sense  and  
caution  are therefore  always  recommended 
for installation, operation and maintenance. 
inverter 
The appliance must be installed in accordance
with applicable national regulations. 
Before accessing the terminals, all the  power 
circuits must be disconnected from the  power 
supply. 
Read this guide before installing and using  the
appliance.
1
The appliance must be fitted with means for 
disconnection from the supply mains having 
a contact separation in all poles that provide 
full disconnection under overvoltage 
category III conditions, and these means 
must be incorporated in the fixed wiring in 
accordance with the wiring rules. 
The appliance shall be installed in accord-
ance with national wiring regulations.
The 
air conditioner must be 
installed by professional or qualified 
persons.