Premium PIA18064A Service Manual

Page of 44
Service manual 
33 
 
0
T-Ts
Room temp. up
Room temp. down
2
Low fan
Med fan
 
8.7.6  Indoor evaporator high-temperature protection at heating mode   
(T=indoor exchanger temp.) 
T
T temp. up
T temp. down
TE7
Compressor on
Fan on
TE8
TE9
Compressor off
Fan off
Compressor on
Fan off
 
8.7.7  The louver opens to Standard Angle ANGLHEAT when power is on for the first time 
 
8.8 
  Defrosting mode (available for heating mode) 
8.8.1  Defrosting condition: Defrosting starts when either of the following 
&
:
 
  A and B are satisfied: 
A: The compressor keeps running for 40 minutes or more. 
B: The temperature difference of evaporator and room temperature meets one of the following: 
TM def.
TA-TS
TH def.
High fan
Med fan
Low fan
TL def.
Breeze
 
 
8.8.2 
  Calculate from the end of latest defrost, evaporator high temp. Protection only closes outdoor 
fan with the compressor still running. Add up to 90 minutes. 
8.8.3    Defrosting time 
At condition 
, If item B is satisfied before item A, it would be regarded as severe frosting and the 
defrosting time is 10 minutes. If item B is satisfied after item A, the defrosting time is 7.5minutes.