Premium PIA18064A Service Manual

Page of 44
Service manual 
37 
 
 
10.  Troubleshooting 
10.1 
  Display board 
 
  Operation 
The indicator flashes once every second after power is on and illuminates when the air conditioner is in 
operation. 
  Timer indicator: 
The indicator illuminates then TIMER is set ON. 
  PRE-DEF. indicator (For cooling & heating mode only) 
The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating. 
At this time, PRE-DEF. indicator illuminates. 
  Auto indicator: 
This indicator flashes when the air conditioner is in AUTO operation. 
  ECON indicator 
This indicator illuminates while the air conditioner is in economic operation. 
 
10.2 
  Troubleshooting 
Failure phenomenon
Operation
lamp
Timer
lamp
Indoor fan speed has been out of control for over 1 minute
X
Indoor room temp. or evaporator sensor  is open circuit or short circuit
On
Over current protection of the compressor occurs 4 times
X
EEROM error
On
No over-zero signal
r Extinguish
☆    Flash at 5Hz