Electrolux EI30DD10KS Installation Instruction

Page of 54
13
Install Ductwork
Install Cooktop
- Align the cooktop with the downdraft and fasten 
cooktop in place.
Connect Downdraft to Power
- Plug the downdraft’s power cord into the outlet.
- Make sure the power cord is routed beneath the 
appliance and away from heat generated by the 
cooktop.
IMPORTANT
All ductworks must be as installed as per local codes.
NOTE
NOTE
Accurate alignment of cooktop and downdraft is 
necessary to ensure that there is no interference 
when air vent is raised and lowered. There should 
be a gap of 1/8” between the back of the cooktop 
and the front of the downdraft cover.
Local building codes must be followed in specifying 
approved type and specifications of ALL duct used. 
Always use an appropriate roof or wall cap with damper.
Screw
Air Flow
Duct Tape Over Seam and Screw
Installation
Re-attach Transition Duct
The Transition Base must be installed with the flange 
at the top. Position the duct Transition Cover on the 
Transition Base for the discharge direction selected. 
The top edge of the duct Transition Cover must be 
under the tabs of the Transition Base.
Down Discharge – Attach the transition with 4 screws 
as shown.
Connect the ductwork
- Use galvanized or aluminum duct in 8” or 10” round 
or 3 ¼” x 14” size, or a combination of both. PVC 
duct should be used if installing under a poured 
concrete slab. Use the shortest and straightest duct 
run possible.
Transition 
Base
Remove Phillips 
Head Screw 
from Left Hole 
and Reattach as 
Shown
Duct Transition 
Cover
(4) Phillips 
Head Screws
(4) Phillips 
Head 
Screws
(4) Phillips 
Head Screws
Remove Phillips 
Head Screw from 
Right Hole and Attach 
as Shown
Discharge Down (as supplied)
Discharge Left
Discharge Right
Discharge
Discharge
Left or Right Discharge – Remove the Phillips head 
screw from the chassis.  Attach the transition with 5 