Electrolux E36IC75FSS Installation Instruction

Page of 16
2
INDUCTION COOKTOP INSTALLATION INSTRUCTIONS
I
H
G
A
Figure 2 – COUNTERTOP CUTOUT OPENING
CAUTION
To eliminate the risk of burns or
fire by reaching over heated surfaces, cabinet
storage space located above the cooktop
should be avoided. If cabinet storage is
provided, risk can be reduced by installing a
range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom
of the cabinets.
* Letters on this figure refer to
chart on front page except for J,
and L.
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min. Clearance
Between the Top of the
Cooking Platform and the
Bottom of an Unprotected
Wood or Metal Cabinet
24" (61 cm) Min. when
Bottom of Wood or Metal
Cabinet is Protected by Not
Less Than 1/8" (0.3 cm) Flame
Retardant Millboard Covered
With Not Less Than No. 28
MGS Sheet Steel, 0.015"
(0.4 mm) Stainless Steel,
0.024" (0.6 mm) Aluminum
or 0.020" (0.5 mm) Copper.
2 1/2" (6.4 cm) Min. From
Edge of Cutout to Front
Edge of Countertop
18"
(45.7 cm)
J
 
Min. From Edge of
Cooktop to Nearest
Combustible Wall
(Either Side of Unit).
12"
(30.5 cm)
10"
( 25.4 cm)
K 
Min. Recommended
Distance Between Rear
Edge of Cutout  and
Nearest Combustible
Surface Above
Countertop
24"
(61 cm)
Install junction box at a
location which will be easy
to reach and that will not
interfere with the cooktop
installation. We suggest 12"
(30.48cm) lower than the
countertop.
If a drawer is present
underneath, allow at
least 10" (25.4cm) of
clearance below the
countertop.
CAUTION
Never store
flammable products in
the drawer.
Min.
L
MODEL
J
K
L
3 6 "
7½" (19.1 cm)
2" (5.1 cm)
36" (91.4 cm)