Electrolux EI32AR80QS Wiring Reference

Page of 1
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT                           
CONTROL SETTING
Capacitor Run or 
Induction Run
70°F (21°C) Ambient
90°F (32°C) Ambient
Operating Time
10 to 20%
20 to 30%
Refrigerator Temperature
35° to 40° F  
2° to 4° C
35° to 40° F  
2° to 4° C
Low Side Pressure  
(cut-in)
25 to 30 psig  
175 to 205 kPa
25 to 30 psig  
175 to 205 kPa
Low Side Pressure      
(cut-out)
10 to 15 psig  
70 to 100 kPa
10 to 15 psig  
70 to 100 kPa
High Side Pressure               
(last 1/3 cycle)
120 to 130 psig  
810 to 880 kPa
175 to 185 psig  
1180 to 1260 kPa
Wattage (last 1/3 cycle)
120 to 180
140 to 155
Amps (running)
.8 to 1.3
1.0 to 1.5
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
19’
37° F (3° C)
47° F (8° C)
550
24
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
2.3
1100 CW Opposite Shaft
0.13 Running
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S ORIGI-
NAL LOCATION
SERvICE DATA SHEET  -   297299900
STANDARD - AUTOMATIC DEFROST 
REFRIGERATOR MODELS (
R134a)
IMPORTANT SAFETy NOTICE
The information provided herein is designed to assist qualified repair 
personnel only. Untrained persons should not attempt to make repairs 
due to the possibility of electrical shock. Disconnect power cord before 
servicing.
IMPORTANT
If any green grounding wires are moved during servicing, they must 
be returned to their original position and properly secured.
 
CAUTION:
 
All electrical parts and wiring must be shielded 
from torch flame. Do not allow torch to contact insulation; it 
will char at 200°F.
NOTE:
 
Products come equipped with an Electronic Defrost Control. 
To  initiate  defrost,  press  and  hold  air  filter  and  alarm  reset  key 
simultainiously for three seconds.  To terminate defrost, press and 
hold air filter and alarm reset key simultainiously for three seconds