Specification Update 
V2. 
BR0# Maximum Hold Time Specification Change 
The BR0# maximum hold time has changed to 2 BCLKs.  This change will be shown in the “System 
Bus AC Specifications (Reset Conditions)” table and “System Bus Reset and Configuration Timings” 
figure of the Mobile Intel
®
 Celeron
®
 Processor on .13 Micron Process in Micro-FCPGA Package 
Datasheet. This change will be incorporated in the next revision of the datasheet. 
Currently it states: 
Table 21. System Bus AC Specifications (Reset Conditions) 
T# Parameter 
Min 
Max 
Unit 
Figure 
Notes 
T45: Reset Configuration Signals (A[31:3]#, BR0# INIT#, SMI#) 
Setup Time 
4  
BCLKs 13  1 
T46: Reset Configuration Signals (A[31:3]#, BR0# INIT#, SMI#) 
Hold Time 
2 20 
BCLKs  13 
NOTES: 
 
1. 
Before the deassertion of RESET#. 
2. 
After clock that deasserts RESET#. 
It should state: 
Table 21. System Bus AC Specifications (Reset Conditions) 
T# 
Parameter 
Min Max  Unit  Figure Notes 
T45: Reset Configuration Signals (A[31:3]#, BR0# INIT#, 
SMI#) Setup Time 
4  
BCLKs 
13  1 
T46:Reset Configuration Signals (A[31:3]#,INIT#, SMI#) 
Hold Time 
2 20 
BCLKs 13 
T47: Reset Configuration Signal BR0# Hold Time 
BCLKs 
13 
NOTES: 
 
1. 
Before the deassertion of RESET#. 
2. 
After clock that deasserts RESET#.