Intel Xeon X3440 BX80605X3440 User Manual

Product codes
BX80605X3440
Page of 106
Thermal Specifications
44
Document Number: 424077 Revision: 2.0Thermal/Mechanical 
Specifications and Design Guidelines
6.1.4
Thermal Metrology
The maximum TTV case temperatures (T
CASE-MAX
) can be derived from the data in the 
appropriate TTV thermal profile earlier in this chapter. The TTV T
CASE 
is measured at the 
geometric top center of the TTV integrated heat spreader (IHS). 
 illustrates 
the location where T
CASE
 temperature measurements should be made. See 
for drawings showing the thermocouple attach to the TTV package.
Note:
The following supplier can machine the groove and attach a thermocouple to the IHS. 
The supplier is listed the table below as a convenience to Intel’s general customers and 
the list may be subject to change without notice. THERM-X OF CALIFORNIA, 1837 
Whipple Road, Hayward, Ca 94544. Ernesto B Valencia +1-510-441-7566 Ext. 242 
ernestov@therm-x.com. The vendor part number is XTMS1565.
6.2
Processor Thermal Features
6.2.1
Processor Temperature
A new feature in the processors is a software readable field in the 
IA32_TEMPERATURE_TARGET register that contains the minimum temperature at 
which the TCC will be activated and PROCHOT# will be asserted. The TCC activation 
temperature is calibrated on a part-by-part basis and normal factory variation may 
result in the actual TCC activation temperature being higher than the value listed in the 
register. TCC activation temperatures may change based on processor stepping, 
frequency or manufacturing efficiencies.
6.2.2
Adaptive Thermal Monitor
The Adaptive Thermal Monitor feature provides an enhanced method for controlling the 
processor temperature when the processor silicon exceeds the Thermal Control Circuit 
(TCC) activation temperature. Adaptive Thermal Monitor uses TCC activation to reduce 
processor power via a combination of methods. The first method (Frequency/VID 
Figure 6-3. TTV Case Temperature (T
CASE
) Measurement Location
  37.5  
  3
7.5 
 
Measure T
CASE
 at 
the geometric 
center of the 
package