Bosch d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 4.0  Schedules (Skeds) 
EN | 107 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
 
W# Open Window Start 
Default: 
00: 00 
Selection: 
HH:MM (hours and minutes) 
Enter the time you want the control panel to start the 
Opening Window. The window goes into effect at the 
beginning of the minute. 
 
Make time entries using a 24-hour clock. 
For example: 
Midnight is entered as 00:00 
7:00 AM is entered as 07:00 
2:45 PM is entered as 14:45 
11:59 PM is entered as 23:59 
This program item is one of three required to create 
an Opening Window. To program an Opening 
Window, Open Early Begin and Open Window Stop 
must also be programmed. Refer to the W# Open 
Early Begin
 prompt on page 106 for explanations of 
report features. 
W# Open Window Stop 
Default: 
00: 00 
Selection:  HH:MM (hours and minutes) 
Enter the time you want the control panel to end the 
Opening Window. The window stops at the end of the 
minute. 
 
 
Make time entries using a 24-hour clock. 
For example: 
Midnight is entered as 00:00 
7:00 AM is entered as 07:00 
2:45 PM is entered as 14:45 
11:59 PM is entered as 23:59 
This program item is one of three required to create 
an Opening Window. To program an Opening 
Window, Open Early Begin and Open Window Start 
must also be programmed. 
If the area is not disarmed by the time the Open 
Window Stop time expires, the control panel 
generates a Fail to Open Report if A# Fail to Open is 
enabled in Area-Wide Parameters. 
Opening Reports generated between the Open 
Window Start time and Open Window Stop time can 
be suppressed by programming A# Disable O/C in 
Window
 as Yes. Refer to the W# Open Early Begin 
prompt on page 106 for additional explanations of 
report features. 
 
Do not use a time of 23:59 as a window 
stop time unless another window begins 
on the next day at 00:00. 
Fail to Open Reports are not sent for 
windows that stop at 23:59. 
 
Figure 5: Example Opening Window Timeline (using two Opening Windows on same day) 
1
2
3
4
5
6
7
8
9
 
1 -  Areas disarmed between midnight and 6 AM 
generate Opening Reports. 
2 -  Areas disarmed between 6 AM and 7 AM 
generate Early to Open Reports. 
3 -  If the area is disarmed between 7 AM and 8 AM 
regular Opening Reports are generated. If 
Disable O/C in Window is programmed Yes the 
Opening Report is not sent to the central station. 
4 -  If the area is not disarmed by 8:01 AM, a Fail to 
Open Event is generated if Fail to Open is 
programmed Yes in Opening and Closing 
Options. 
5 -  If the user disarms the area between 8:01 AM 
and 12:59, PM a Late to Open Event is 
generated. 
6 -  Areas that are disarmed between 1 PM and 2 
PM generate Early to Open Reports. 
7 -  If the area is disarmed between 2 PM and 3 
PM regular Opening Reports are generated. If 
Disable O/C in Window is programmed Yes, 
the Opening Report is not transmitted to the 
central station. 
8 -  If the area is not disarmed by 3:01 PM, a Fail to 
Open Event is generated if Fail to Open is 
programmed Yes in Opening and Closing 
Options. 
9 -  If the user disarms the area between 3:01 PM 
and 11:59 PM, a Late to Open Event is 
generated.