Bosch d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 4.0  Schedules (Skeds) 
EN | 109 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
If the window must activate on the same day as it is 
programmed, reboot the control panel to activate the 
window immediately.  
W# Close Window Start 
Default: 
00: 00 
Selection: 
HH:MM (hours and minutes) 
Enter the time that you want the control panel to start 
the Closing Window. The window goes into effect at 
the beginning of the minute. 
00:00 is midnight, 23:59 is 11:59 PM. Make entries 
using a 24-hour clock (for example, 7:00 AM is 
entered as 07:00, 2:45 PM is entered as 14:45). 
This program item is one of three required to create a 
Closing Window. To program a Closing Window, 
Close Early Begin and Close Window Stop must also 
be programmed. 
If the area is not armed when the Close Window Start 
time comes, a warning tone sounds and PLEASE 
CLOSE NOW appears at the keypad. To temporarily 
silence the tone, press the [ESC] key on the keypad. 
The warning tone restarts in 10 min if the area is not 
armed. 
Refer to the W# Close Early Begin prompt in this 
section for explanations of report features. 
W# Close Window Stop 
Default: 
00: 00 
Selection:  HH:MM (hours and minutes) 
Enter the time that you want the control panel to end 
the Closing Window. The window stops at the end of 
the minute. 
00:00 is midnight, 23:59 is 11:59 PM. Make entries 
using a 24-hour clock (for example, 7:00 AM is 
entered as 07:00, 2:45 PM is entered as 14:45). 
This program item is one of three required to create a 
Closing Window. To program a Closing Window, 
Close Early Begin and Close Window Start must also 
be programmed. 
If the area is not armed by the time the Close 
Window Stop time expires, the control panel 
generates a Fail to Close Report if enabled in Fail To 
Close. 
Closing Reports generated between the Close 
Window Start time and Close Window Stop time can 
be suppressed by programming Disable O/C in 
Window
 as Yes. Refer to the W# Close Early Begin 
prompt for other explanations of report features. 
Do not use a time of 23:59 as a window stop time 
unless the window continues on the next day at 
00:00. Fail to Close Reports are not sent, and the 
Auto Close feature does not work for windows that 
stop at 23:59. 
Do not program a single window to cross the 
midnight boundary. The window stop time must be 
later than the window start time. To program a 
window that effectively crosses the midnight 
boundary, you must program two windows. 
For example, to program windows for an area that 
closes between 11:30 PM and 12:30 AM, five days a 
week, use two windows as shown in Table 32
Table 32: Programming Example: Linking Two Closing Windows over Midnight 
 
Open Close 
W
Day of Week 
Early 
Begin
 
Start
 
Stop 
Early 
Begin
 
Start
 
Stop 
eXcept 
On 
Holiday 
Holiday 
Index 
Area(s) 
1  S  M  T  W  T  F  S 
 
 
 
22 : 00 
23 : 30 
23 : 59 
Yes    No 
1   2   3   4 
 2  3  4  5  6  7  8 
2 S 
 
M  T  W  T  F  S 
 
 
 
00 : 00 
00 : 00 
00 : 30 
Yes    No 
1   2   3   4 
 2  3  4  5  6  7  8