5.0 AUXPARM 
5.1 Introduction 
The programming prompts in this section are 
primarily used for programming enhanced 
communication capabilities for the GV3 Series 
Control Panels. 
Enhanced communications is the ability to provide 
communication functions for the control panels over 
SDI. These communication methods include: 
  Routing control panel events through a network 
interface module (NIM). A network interface 
module (NIM) can be a DX4020 or an ITS-
DX4020-G. 
  Communicating with remote programming 
software (RPS) using a (NIM). 
  Communicating with a remote or local automation 
software package. 
5.2 RPS 
Requirements 
The AUXPARM section currently has seven sections:  
  SDI Automation 
  SDI RPS Parameters 
  Enhanced Communications 
  SDI RPS/Enhanced Communication 
Configuration 
  Miscellaneous 
  Cross Point Parameters 
  Route Group Rate 
 
 
5.3 SDI 
Automation 
SDI automation defines the characteristics of a serial 
interface module (SIM) when used with home or 
business automation software. The SIM is a two-way 
SDI to a serial communication module that allows the 
control panels to send and receive information to and 
from an external software program.  
 
The SIM can be a D9133, DX4010i, or 
DX4020 (configured to emulate serial 
communication). 
A DX4010i can be used only for 
programming. 
This automation protocol allows external software 
programs to interact and perform functions such as:  
  arming and disarming areas, 
  changing user passcodes and names, and  
  turning relays on and off. 
The items described in this section allow some 
simple configuration options. To receive the SIM 
automation protocol; however, you must contact 
Bosch Security Systems, Inc. Technical Support at 
(888) 886-6189. 
Enable SDI Auto 
Default: 
No 
Selection: 
Yes or No 
Yes 
Enable Automation software. 
No Disable 
Automation 
software. 
Changing this item to Yes enables the automation 
address (SDI Address 80). 
Supervise SDI 80 
Default: 
No 
Selection: 
Yes or No 
Yes 
Supervise the serial interface 
module (SIM). 
No 
Do not supervise the serial interface 
module (SIM). 
This item determines whether the serial interface 
module (SIM) is supervised or not. If the SIM is 
supervised, disconnecting the SIM from the control 
panel creates a Trouble SDI 80 Event and the 
keypad annunciates a trouble tone (if programmed) 
and displays SERVC SDI 80. 
 
Trouble SDI 80 Reports are always sent 
using the account number for Area 1.