D9412GV3/D7412GV3 | Program Entry Guide | 6.0  ACCESS CONTROL 
EN | 140 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
 
Table 38: Cross Point Ranges Within Groups 
 
Cross Point 
Group Point 
Range 
to 
2 9 
to 
16 
17 
to 
24 
4 25 
to 
32 
33 
to 
40 
6 41 
to 
48 
49 
to 
56 
8 57 
to 
64 
65 
to 
72 
10 73 
to 
80 
11 
81 
to 
88 
12 89 
to 
96 
13 
97 
to 
104 
14 105 
to 
112 
15 
113 
to 
120 
16 121 
to 
127 
17 
129 
to 
136 
18 137 
to 
144 
19 
145 
to 
152 
20 153 
to 
160 
21 
161 
to 
168 
22 169 
to 
176 
23 
177 
to 
184 
24 185 
to 
192 
25 
193 
to 
200 
26 201 
to 
208 
27 
209 
to 
216 
28 217 
to 
224 
29 
225 
to 
232 
30 233 
to 
240 
31 
241 
to 
247 
 
Refer to Section  2.3 Routing on page 17 for 
information about programming the destination (for 
example, the central station) for Unverified Events. 
An Unverified Event does not produce a 
corresponding Restoral Event. 
The Cross Point function applies only to alarm 
conditions. It does not apply to supervisory or trouble 
conditions. Points programmed with point response D 
(Delayed) eventually enter into an alarm condition if 
the area is not disarmed in time. 
 
 
Cross Point Time 
Default: 
20 sec 
Selection: 
5 sec to 255 sec 
Select the amount of time (in seconds) that points 
within a Cross Point Group are in alarm before a 
Cross Point event is generated. 
 
6.0 ACCESS 
CONTROL 
 6.1  Door Profile 
This programming category is used to: 
  Assign an area that also activates the D9210B 
  Assign a point to the door 
  Program the door state to change the time when 
the arm state changes 
  Allow for the Strike relay to activate upon a fire 
alarm 
  Programming the Interlock point. 
Door # 
Default: 
Selection: 
1 to 8 
Enter the number of the door you are programming. 
 
The D9412GV3 supports up to eight 
doors. The D7412GV3 supports two 
doors. 
D# Entry Area # 
Default: 
Selection: 
0 to 8 
1 to 8 
The area assigned to the door 
controller to which the reader allows 
access. 
Door controller does not function. 
Assign an area to the door controller. This entry 
allows the D9210B to be polled, activating 
communication to the control panel. This is also the 
area a user exits when initiating an REX. 
 
The D# Entry Area # prompt for the 
D9412GV3 is limited to the first 8 areas.