7.0 SIA CP-01 Quick Reference
Table 40: Programming the Control Panels for SIA CP--01 Compliance
Prompt Name
Bosch Recommended Settings
for SIA CP-01 Compliance
for SIA CP-01 Compliance
Shipping Default
References
Phone #
(Prefix backup phone number with
Call Waiting disable command)
Call Waiting disable command)
{Blank}
Page 12
Duress Type
Option 3
0 (disabled)
Page 36
Cancel Report
Yes
Yes
Page 36
A# Exit Dly Time
45 sec to 255 sec
60 sec
Page 38
A# Duress Enable
Yes
No
Page 39
A# Exit Restart
Yes or No
Yes
Page 49
A# Arm No Exit
Yes or No
Yes
Page 49
A# Two Man Rule
No No
Page
47
A# Early Ambush
No
No
Page 48
A# Exit Warning
Yes Yes
Page
49
A# Entry Warning
Yes
Yes
Page 50
A# Burg Time
1
6 min to 90 min
6 min
Page 42
A# Alarm Bell
1 to 128(64), A, B, C
A (on-board alarm output)
Page 79
CC# Entry Tone
Yes or No
Yes
Page 54
CC# Exit Tone
Yes or No
Yes
Page 54
CC# Abort Display
Yes or No
Yes
Page 56
CC# Cancel Display
Yes or No
Yes
Page 56
Master Arm Instant
- -
Page
60
Perimeter Instant
-
-
Page 60
L## Send Duress
- or E
E
2
Page
75
L## Disarm
- or E
E
2
Page 67
L## Passcode Disarm
- or E
E
2
Page
75
P## Entry Delay
30 sec to 240 sec
30 sec
Page 92
P## Alarm Abort
Yes or No
Yes
3
Page
101
Abort Window
15 sec to 45 sec
30 sec
Page 137
Passcode Length
3 to 6 digits
Disabled
Page 138
Swinger Count
1 to 2 trips
1 trip
Page 138
Remote Warning
Yes Yes
Page
138
Cross Point Time
5 to 255 sec
20 sec
Page 140
P## Cross Point
Yes or No
No
Page 99
1 The SIA allowed range is 1 min to 90 min. Must additionally comply with UL requirements, refer to section A# Burg Time.
2 L14 is the default duress user index.