A# Fail to Close 
Default: 
No 
Selection:  Yes or No 
Yes 
Fail to Close Report is sent for this 
area if the area is not armed when 
the Closing Window stop time occurs. 
Note:   
Program an exit delay time in 
Exit Dly Time
No 
Fail to Close Report is not sent for 
this area. 
  If Auto Close is programmed 
Yes, a Fail to Close Report is 
sent because it occurs when the 
Closing Window stop time 
occurred. 
  If Disable O/C in Window is 
Yes, the Fail to Close Report is 
followed by Closing Late or 
Force) Close Late. 
This item determines if a Fail to Close Report is sent 
for this area. Use to determine if a user failed to arm 
the area before the Closing Window expires. Normal 
Opening and Closing Reports do not need to be 
programmed to use this feature. 
A# Restrictd O/C 
Default: 
No 
Selection:  Yes or No 
Yes 
Restrict Opening and Closing 
Reports for this area. A# Area O/C 
must be programmed Yes to 
generate Restricted Opening and 
Closing Reports. 
Note:  
If a passcode is not required for 
arming or disarming and this item 
is Yes, the area sends only 
Restricted Opening and Closing 
Reports. In this case, Restricted 
Reports are sent without User ID. 
Opening/Closing Window does not 
affect this report. Windows do not 
prevent sending Restricted Opening 
and Closing Reports from being sent. 
Early or late designations are not 
added to Opening or Closing Reports 
when they are sent according to the 
rules for Restricted Opening or 
Closing Reports. 
No 
Do not Restrict Opening and Closing 
Reports for this area. 
Regardless of programming in 
Authority Levels L## Restricted O/C
reports are not restricted in this area 
when this item is programmed as No
Note:  
Was Force Armed and Forced 
Close Events can still be sent to 
the central station if enabled in 
Routing when force arming the 
system. 
This item determines if this area can restrict Opening 
and Closing Report activity. 
A Restricted Opening Report refers to the control 
panel sending an Area Opening Report only when 
the area is disarmed after a non-fire alarm. 
A Restricted Closing Report refers to the control 
panel sending a Force Closed Report only when the 
area was master armed with Controlled points that 
were faulted during the arming sequence. The 
sequence of reports generated by a restricted closing 
is: Was Force Armed, Forced Point, and Force 
Closed.