Bosch d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 48 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Parameter Setup Requirement:  
Two Man Rule can be completed only by entering 
two valid unique passcodes with L## Passcode 
Disarm
 authority. 
 
To avoid unintended results for the end 
user of the system: 
  Set CC# Scope to Area Wide for 
keypads assigned to areas with the 
Two Man Rule feature. 
  Avoid setting the A# Two Man Rule 
to Yes in an area where A# Early 
Ambush
 is set to Yes
 
 
Use this feature in banks or other facilities 
that might require a higher level of 
security to gain access to a vault or other 
protected area. 
D1255 Keypad 
After the first valid passcode is entered, the D1255 
replaces the scrolling DISARM NOW and the Point 
Text display with the SECOND CODE:.display 
When the user presses the first digit of the second 
code, the display changes to SECOND CODE:  *.  
SECOND CODE: appears for 19 sec. If no digits are 
pressed, the display returns to normal and the area 
does not disarm. If a second code is entered, the 
area disarms and an Opening report is sent with the 
User ID of the first user. If the second code entered is 
the same as the first code, is invalid, or does not 
have L## Disarm authority, the keypad shows NO 
AUTHORITY and returns to idle text or entry delay. 
D1260 Keypad 
In the D1260, after the first valid passcode is entered, 
the following message appears for 3 sec.  
 
Then the next message appears requesting a second 
code. 
 
When the first digit of the second code is pressed, 
the following message appears. As each digit is 
pressed, an additional asterisk appears. 
 
 A# Early Ambush 
Default: 
No 
Selection:  Yes or No 
Yes 
Two valid passcodes are required to 
disarm the area within the time period 
specified in Early Ambush Timer. The 
second valid disarm passcode must 
be entered within a time limit. Refer 
to Early Ambush Timer on page 
137. 
If the second passcode is not entered 
within the time limit, the system 
generates a Duress Event based 
upon the primary user. 
No 
A single passcode with a valid 
authority level can disarm the area. 
The Early Ambush disarming feature is intended for 
use when you disarm an area that is in the Master 
Armed state, but it can also be used with the 
Perimeter and Instant Armed states. After the first 
valid passcode is entered, the area is disarmed and 
the keypad displays the disarmed idle text normally. 
This function operates only when you use Passcode 
Disarm. 
If the second valid disarm passcode is entered, the 
D1255 Keypad shows CODE 2 VALIDATE and 
sounds the Watch Mode tone. Only the Watch Mode 
tone appears on the D720 Keypad.  
The D1260 Keypad sounds the Watch Mode tone 
and the following text appears.