Bosch d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 60 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
2.10.1 Commands 
Similar to command initiation used in other Bosch 
Security Systems, Inc. products, the Commands 
method provides continuity in the arming commands 
across product lines and makes an easy transition for 
dealers using other Bosch Security Systems, Inc. 
products. With commands, the end user presses 
[COMMAND] and then the numeral of the command 
to initiate. For example, [COMMAND][2] arms the 
perimeter of the area. Some prompts can be 
accessed only from a menu. These prompts are 
indicated by (Menu Function only). To access these 
functions, press [MENU], enter the function number, 
and use the [PREV] and [NEXT] keys to scroll 
through the choices. 
The D9412GV3/D7412GV3 Program Record Sheet  
(P/N: F01U170809) lists the commands available 
with the system. Command numbers are shown in 
the column labeled Command. If a particular function 
does not have a command number, it can be 
accessed only through the Function List. 
If you plan to use only commands to operate the 
system, and to arm and disarm by entering a 
passcode, you do not need to program Custom 
Function or Function List. 
2.10.2 Command Authorization 
Programming choices in this section determine if 
keypad functions are disabled (-), enabled (E), or 
passcode (P) restricted.
 
Table 24: Keypad Programming Choices 
 
Selection Description 
Disable the function panel-wide. 
The keypad shows NO 
AUTHORITY if you access the 
function using a command or the 
Function List. 
Enable the function panel-wide. 
The function can be executed 
without entering a passcode. 
Passcode required. When the 
passcode is entered at the 
keypad, the control panel checks 
the user’s authority level. Refer to 
Section 2.10.6 Authority Level 
Selections
 on page 66. 
 
 
 
Refer to Section 2.10.6 Authority Level 
Selections 
on page 66 for a detailed 
description of the functions on the 
following pages. These parameters 
determine only if the authority level 
functions are passcode protected. 
Master Arm Delay
 
Default: 
Selection:  -, E, or P 
Passcode: Required for all users with 
Master Arm Delay enabled for their 
authority level. 
Enable: A user does not need a 
passcode to use [COMMAND][1]. 
Disable Master Arm Delay cannot be 
accessed in the function menu or 
started with a command even if this 
function is enabled for the user’s 
authority level. 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Master Arm Delay  [COMMAND][1] 
Use this arming function to master arm disarmed 
areas. If enabled, the following arming choices are 
available to the user with this authority. 
Master Arm Instant 
Default: 
- (Disabled) 
Selection: 
-, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Master Arm 
Instant 
[COMMAND][1][1] 
Use this arming function to master arm instant areas 
that are disarmed. Entry and exit delays are not 
provided with this arming function. This causes a 
Perimeter and Interior Delay point to act as an Instant 
point. 
For SIA CP-01 Compliance 
 
This feature is not allowed to be used 
with SIA CP-01 compliant installations. 
 
 
Perimeter Instant 
Default: 
- (Disabled) 
Selection:  -, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Perimeter Instant 
Arm 